Intended and Prohibitive use 

Intended use 

Removal of Coatings. 
Hold cleaning, general deck and surface cleaning, removal of heavy rust on tankers and dry dock 
applications . 
Tank descaling, Descaling of structures prior to painting. 
Paint removal. 
Other industrial coating removal from floors and other surfaces. 
Removal of concrete residue from re-bar Cleaning cement from plant and vehicles
Weld cleaning. 

Prohibitive use 

Any use in an explosive atmosphere is prohibited. 
Use on materials containing asbestos is prohibited. 
Use by an underage, untrained or person who is under the influence of drugs or alcohol.
Use with non-genuine spare parts or accessories is prohibited. 

Safety check before operating the Needle Scaler 

1.  Read section in "Operating and safety precautions". 
2.  Make sure the electric supply is consistent with the electric motor requirements. The scaler 

comes with a standard cable length  of 2.5 meters, avoid using a longer cable to to avoid voltage 
drop.  

3.  Connect the supply cable as shown. The Male portion is connected to the Scaler (Factory fitted).

The female side electrical connection to be made a t customer end as per the model no. and 
supplied voltage. 

  First lift the cover and pull the plug from the assembly.  

  Now remove the screws from the inner side of female plug. This will allow to remove the

portion and connection points will available. Refer below figure for wire connection.

 

Connection detail for  1-phase  

 

First disassemble the male & female plug by lifting spring loaded lock. 

  
 
 
 
 
 
 
 
 
 
 
 

 

 

 FF-MM-319-Rev0 

Page 3 

Hold cleaning, general deck and surface cleaning, removal of heavy rust on tankers and dry dock 

bar Cleaning cement from plant and vehicles.  

under the influence of drugs or alcohol. 

electric motor requirements. The scaler 

onger cable to to avoid voltage 

Connect the supply cable as shown. The Male portion is connected to the Scaler (Factory fitted). 
The female side electrical connection to be made a t customer end as per the model no. and 

Now remove the screws from the inner side of female plug. This will allow to remove the rear 
portion and connection points will available. Refer below figure for wire connection. 

First disassemble the male & female plug by lifting spring loaded lock. 

 

Summary of Contents for ENS100V

Page 1: ...perating or servicing this Scaler It s the responsibility of the employer to ensure this manual is read by the operator Please preserve this manual This document issued with Model No Product Serial Number are trademarks of Teryair Equipment Pvt Ltd Operation and Maintenance Guide IMPA Number 59 12 01 59 12 03 Read this manual carefully before installing operating or servicing this Electric Needle ...

Page 2: ... allowed to operate this Electric Needle Scaler Operators must be made familiar with the instructions in this manual before attempting to operate the Electric Ensure that job site is clear of bystanders Caution Use only genuine Teryair or Teryair approved accessories Warning This Electric Needle Scaler is not designed for use in an explosive environment ENS100V ENS200V IMPA Number equivalent 59 12...

Page 3: ...t being prepared Do not hold the exposed needles whilst the Electric Needle Scaler is in use this could cause vibration damage to the hands Do not drag this Electric Needle Scaler by the cable Warning Do not use the Electric Needle Scaler in potentially explosive environments Safety wear mandatory while operating needle scalers Eye and face and ear protection must be worn at all times during opera...

Page 4: ... The Male portion is connected to the Scaler Factory fitted The female side electrical connection to be made a t customer end as per the model no and supplied voltage First lift the cover and pull the plug from the assembly Now remove the screws from the inner side of female plug This will allow to remove the portion and connection points will available Refer below figure for wire connection Conne...

Page 5: ...to give you years of satisfactory service Follow the instructions mentioned here to enhance life and performance of your scalers Use genuine Teryair spares and if possible mention the serial number of the Electric when ordering spares FF MM 319 Rev0 Page 4 Now remove the two screws as shown to remove the rear cover of female plug to see Insert the cable from the back of the cover through the holde...

Page 6: ... new one and assemble in reverse manner Carbon Brush Replacement Remove the screws 26 from bottom to disassemble the cover 25 Now remove the cap 22 and pull the carbon brush 21 Replace with new one and assemble in reverse manner Needle size Needle Part no Needle Supporter Ø2 022 90 08 53 No s 022 40 47 Ø3 022 90 04 23 No s 022 40 45 FF MM 319 Rev0 Page 5 Now slide out the needle supporter 13 along...

Page 7: ...5 40 06 Gasket 6 655 21 05 Inner Anvil 1 1 20 655 40 07 O Ring 7 655 40 01 Rubber Grip 1 1 21 655 98 01 Carbon Br 8 655 40 02 O Ring 1 1 22 655 08 02 Cap 9 655 40 03 O Ring 1 1 23 150 40 26 Allen Bolt 10 655 40 04 O Ring 1 1 24 536 90 04 Spring Washer 11 655 51 01 Spring 1 1 25 655 31 01 Back Guard 12 022 90 04 Needle 23 23 26 655 90 01 Self Tapping Screw 13 022 40 45 Needle Supporter 1 1 27 653 9...

Page 8: ...FF MM 319 Rev0 Page 7 ...

Reviews: