background image

 
 
 

 

3/4 

 

Figure 1 - TPS2 Power Relay in TERA System for Regulating Radon Concentrations

  

 

3

 

Scope of Delivery  

 

TPS2 Power Relay including 3x 1m cables 

 

Operation Manual 

  

4

 

Product specification 

Product 

TPS2 Power Relay 

Type symbol 

042 127 171 000 

Vsupply power supply  

230V/50Hz 0,5VA 

Automatic control  

The actuator TAR2,  Central Unit or external switch 
(12V/20mA) 

Vsw maximum switching capacity 

 

1500 VA AC (250V/6A) 

 

5

 

Safety 

Installation  and  connection  of  the  device  may  only  be  carried  out  by  a  specialist  with  relevant 

qualification who is perfectly familiarized with this manual and device function. 
Always make sure that there is no power in a connected device before proceeding with the installation.

 

 

6

 

Operating Instruction and Electrical Connection 

Electrical connection of TPS2 power relay into system is in figure 2. Power relay can switch power load 

on  cable  ´Vsw´ 

up  to  1500VA  (6A/250V)

The  TPS2  po

wer  relay  is  powered  via  cable  ´

Vsupply

´

  from 

230V/50Hz.  Automatic  remote  control  of  power  relay  is  ensured 

by  cable  ´

Automatic  Control

´.  This  cable 

can  connect  Actuator  or  Central  Unit  which  are  parts  of  TERA  program  made  by  TESLA;  see 

http://www.tesla.cz/

 and 

http://www.tesla.cz/

  or other external switch (12V/20mA) to TPS2. By a  switch 

on  box  of  power  relay  it  is  possible  to  choose  permanent  switching  of  relay 

 

position  ´

ON

´

  or    choose 

switching of relay by automatic control signal 

 position 

´

AUT

´

 