26
ENG
Step 7: Connecting Fresh Air Pipe and place the filter
1. According to the wall hole position, select the appropriate piping mode.
Mode1: Left, together with refrigerant piping ,the drainage pipe, and connecting cables.
Mode2: Right, together with refrigerant piping ,the drainage pipe, and connecting cables.
Mode3: Back, single hole for fresh air pipe.
2. Assembly the connector.
For Mode1 (Left) and Mode 2 (Right), insert the straight connector (With foam) into the long end of the Elbow
connector.
3. Connect the pipe to connector.
Align the end of the straight connector(with foam) and the connection end of the pipe, contrarotate the
connector till fully connect to pipe.
4. Determine the pipe length
According to the installation environment, determine to adjust the length of fresh air pipe.
Shorten the length
Just cut one side of the pipe to your desired length.
Increase the length
As the desire length, determine to cut the pipe connected with the connector or not, then take another pipe,
follow the picture to connect the two pipes and use a tape to tighten the joint.
No cut, just connect two pipes by contrarotate them into the straight connector
Cut one pipe as 4, then connect the two pipes
Straight connector
Straight connector(with foam)
Elbow connector
Mode 1 (Left) and Mode 2 (Right)
Mode3 (Back)
Cut somewhere
Summary of Contents for TT37AF-1232IAW
Page 353: ......
Page 354: ...www tesla info ...