- 15 -
3. General data
The accuracy relates to 1 year at a temperature between 18°C – 28° and 75%
humidity (yearly calibrations are offered).
Autoranging and manual measurement range selection
Max. voltage between the connection socket and ground: 400 V
DC/AC
Fusing:
F 200 mA(4 A)/400 V quick-blow fuse
Max. operating height:
2000 m above MSL
Height of display:
200 mm, LCD
Display:
Max. 1999 (3½ )
Polarity
indicator
Automatic
Overrange indicator:
‘OL' is displayed
Sampling
rate:
Approx.
0.4
s
Low battery status:
Battery symbols is displayed
Automatic power off
After approx. 15 min
Power supply:
2 x 1.5 V AAA Micro
Operating temperature:
0 °C to 40 °C
Storage temperature:
-10 °C to 50 °C
Dimensions:
143 x 72 x 33 mm
Weight:
400
g
incl.
batteries
Test
Standard:
IEC/EN
61010-1
Volts DC:
RANGE
RESOLUTION
ACCURACY
200 mV
0.1 mV
± 0.5% of rdg. + 3
digits
2 V
0.001 V
± 0.8 % of rdg.
20 V
0.01 V
+ 5 digits
200 V
0.1 V
400 V
1 V
Input impedance: 10 M
Ω
Max. input voltage 400 V DC