Temperature
Set the selector switch to "TEMP / °C". Place the supplied temperature
probe into the sockets "COM" and V/
Ω
/TEMP/CAP. Touch the object to be
measured with the measuring tip. Read measurement value on the display.
Measurement range
Resolution
Accuracy
-20 to 0 °C
± 5 % + 5 digits
0 to 400 °C
± 2 % + 3 digits
400 to 1000 °C
1 °C
± 1 % + 3 digits
Frequency
Set the selector switch to "Hz". Insert the black test lead into the ‘COM’
socket and the red test lead into the V/
Ω
/TEMP/CAP socket. Using the test
probes, touch the test points of the test circuit. Read measurement value on
the display.
Measurement range
Resolution
Accuracy
20 kHz
10 Hz
± 1.5 % + 10 digits
-Sensitivity: 200 mV
-Max. input voltage 10 Vrms