Test ranges
Testboy
®
TV 225
23
ENG
LI
SH
ENG
LI
SH
ENG
LI
SH
Test ranges
Range
Resolution
Accuracy
Comment
DC voltage
± 0.8 % + 3 digits
Min. 0.2 V
Input impedance
2 MΩ
Max. 600 V
effective
6 V
0.001 V
60 V
0.01 V
600 V
0.1 V
AC voltage
± 1.2 % + 3 digits
6 V
0.001 V
60 V
0.01 V
600 V
0.1 V
Alternating current
40 – 65 Hz
Min. 0.15 A
Max. 3000 A
effective
40 – 1000 Hz
60 A
0.01 A
± 3.0 % + 5 digits
600 A
0.1 A
3000 A
1 A
65 – 400 Hz
60 A
0.01 A
< 1000 A ± 3.0 % + 5
digits
600 A
0.1 A
3000 A
1 A
Frequency
± 0.5 % + 2 digits
Sensitivity:
3 A 40 Hz – 1 kHz
0.5 V 40 Hz – 10 kHz
40 Hz – 1000 Hz
0.1 Hz
1 kH – 10 kHz
1 Hz
Resistance
± 1.0 % + 3 digits
Max. 600 V
effective
6 kΩ
0.001 kΩ
60 kΩ
0.01 kΩ
600 kΩ
0.1 kΩ
6 MΩ
0.001 MΩ
Summary of Contents for TV 225