Preparing for first-time use
Testboy
®
TV 470
61
ENGLISH
DC voltage measurement up to 200V DC / AC current measure-
ment up to 200 V AC
(Only in manual mode, no storage)
Illustration 9
Connect the test leads to GND and PELV as shown in the Illustration. To ac-
tivate the manual mode, change "Auto-measurement" to "No" in the menu.
Then press "Measure" in the main menu and choose the desired measure-
ment (DC or AC). Confirm by pressing the "Select" key. The measured value
is displayed. If the measured value exceeds 25 V, LED3 illuminates (red)
(exceeding the device low voltage range).
Summary of Contents for TV 470