background image

10

1.

Safety instructions

This chapter gives general rules which must be followed

and observed if the product is to be handled safely.

Avoiding personal injury/damage to equipment

i

Do not use the measuring instrument and sensors to
measure on or near live parts.

i

Never store the measuring instrument/probe together
with solvents and do not use any desiccants.

Product safety/preserving warranty claims

i

Operate the product only within the parameters
specified in the Technical data.  

i

Always use the product properly and for its intended
purpose. Do not use force. 

i

Do not expose handles and feed lines to temperatures in
excess of 70 °C unless they are expressly permitted for
higher temperatures. Temperatures given on
probes/sensors relate only to the measuring range of the
sensors.

i

Open the product only when this is expressly described
in the documentation for maintenance and repair
purposes. 
Carry out only the maintenance and repair work that is
described in the documentation. Follow the prescribed
steps when doing so. For safety reasons, use only
original spare parts from testo.

Ensure correct disposal

i

Send the product back to testo at the end of its useful
life. We will ensure that it is disposed of in an
environmentally friendly manner. 

1. Safety instructions

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

Summary of Contents for 0636 6160

Page 1: ...n Meaning Comments Warning advice Warning Read warning advice carefully and take the precautionary measures indicated Serious physical injury could occur if you do not take the precautionary measures...

Page 2: ...Do not expose handles and feed lines to temperatures in excess of 70 C unless they are expressly permitted for higher temperatures Temperatures given on probes sensors relate only to the measuring ra...

Page 3: ...such as CM method or Darr W ge dry and weigh method The probe is not calibratable For connection to testo 635 1 Art no 0560 6351 and testo 635 2 Art no 0560 6352 The product must not be used in the f...

Page 4: ...of approx 5 cm The following factors can influence the measurement result Factors Ideal condition Measurement depth Material thickness 5 cm 2 Caution The upper layers of the material influence the mea...

Page 5: ...to contact surface Slowly increase contact pressure to 1 to 3 kg 2 2 to 4 4lb until a stable value is shown In order to be able to evaluate a moisture course several measurements at different positio...

Page 6: ...stomer service 6 Technical data Characteristic Values Parameters Water content in weight percent of dry mass Measuring ranges Woods 50 Building materials 20 Resolution 0 1 Probe Contact plate integrat...

Page 7: ...limber 9 3 by weight Chipboard 8 by weight Cement screed 3 by weight Anhydrite screed 0 5 by weight Concrete 2 2 by weight Solid brick 1 by weight High insulating brick 2 5 by weight Limestone 1 3 by...

Reviews: