On the job...

Application notes: Programming the logger

Connect the PC to the data logger via interface and start
the “Comsoft.exe” program.

Activate the instrument driver for the testostor 171 data
logger series in 

INSTRUMENT / 

“NEW DEVICE” and

click on the “Next” button.

Once you have selected the correct interface, click
on “Next”.

Enter name and click on “Finish” button

If no other name is entered in Diagram 4, Diagram
5 appears, if communication has been successful,
with a newly setup testostor 171 instrument
serial number.

Requirements/Installation

Minimum system requirements

•  PC with operating system

-  Microsoft Windows 95 or newer 

(if compatible)

-  Microsoft Windows NT 4, Service pack 4, or newer 

(if compatible).

-  Windows 2000 or newer (if compatible).

•  CD Rom drive
•  Pentium 100 MHz
•  32 MB RAM
•  15 MB hard disk
•  Free serial interface (COM) or corresponding adapter.

Installation

1. Place CD ROM in drive
2. The installation menu starts automatically. If it fails to

appear, please click twice on “Setup.EXE” on the CD-
ROM.

3. You are asked to enter licence number (see sticker

on CD-ROM).
It may be necessary to reboot when installing for the
first time.
Note: If the number entered is not accepted, check 
- if the caps key is activated?
- if “Num” in the separate digit block is activated?
- if l was entered instead of 1?
- if o was entered instead of 0?

4. Installation is carried out following confirmation and

you are asked to enter your name and company
name.

5. The procedure continues driven by the menu. Please

note the information and explanations beside the
buttons.

General information on using and installing software

The software environment (how it looks, operation
philosophy ) is defined in accordance with Microsoft®
Office Standard. Symbols and menu items are selected
in accordance with this standard. You will very quickly
get used to working with this environment, if you are
already familiar with Office programs (Word®, Excel®,
PowerPoint® ...).

The instructions in this

manual presume you are

familiar with WINDOWS

®

.

If you are not, please read

your WINDOWS

®

manuals

to get acquainted with the

system and its workings.

Note: 
If you activate

“Protected”  during

installation, the “Range of
functions” register will be be
unavailable to the user and
will not be available in the
future. 

Summary of Contents for Testostor 171

Page 1: ...testostor 1 17 71 1 Data logger and software module Instruction Manual and Software Description...

Page 2: ...2 On the job Installation 12 Programming the logger Application information 13 Reading the memory Application information 15 Error messages 16 Humidity calibration 17 Adjustment 19 Changing batteries...

Page 3: ...ation The testostor 171 1 171 2 1722 171 3 171 4 and 171 6 logger housings come under protection class IP 65 the testostor 171 0 logger housing comes under protection class IP 68 the testostor 171 8 l...

Page 4: ...trument driver sets up communication between the testostor 171 series and your PC Optimum use of all the functions is only possible with the mouse i e your PC must have two free interfaces COM1 and CO...

Page 5: ...internal 10 to 50 C X 50 to 120 C X X X external Type K TE plug in connection 200 to 1100 C X Type T TE plug in connection 50 to 350 C X Resolution 0 1 C X X X X X X X X 1 C from 250 C X Accuracy in p...

Page 6: ...suring head 0602 0092 Sensor Thermocouple Measuring range 60 to 130 C Short term to 280 C t99 5 s Clamp probe 0602 4692 Sensor Thermocouple Measuring range 50 to 100 C Cable length 1 2 m t99 5 s Magne...

Page 7: ...d to enter licence number see sticker on CD ROM It may be necessary to reboot when installing for the first time Note If the number entered is not accepted check if the caps key is activated if Num in...

Page 8: ...mouse button on the testostor 171 icon and select INSTRUMENT SELECTION If communication between the PC and the data logger has been successful the window opposite appears with the status information...

Page 9: ...ate humidity probe is included with the calibration set which you can attach to the 12 mm probe Screw the probe together with the adapter into the container the standard protective cap should remain o...

Page 10: ...anteed that the logger sensor system and the reference instrument have the same climatic conditions the same temperature is particularly important The humidity containers are not needed for this fine...

Page 11: ...aved measured data is lost the calibration data is saved In case of emergency please contact an authorised service point You can change the battery yourself using the battery set which is available as...

Page 12: ...limit values are exceeded or are not reached acoustically and optically You can call up a table summarizing the number of times the limits have been exceeded by clicking twice in the limit value on t...

Page 13: ...dings The total number of readings to be recorded per channel corresponding to your input for Start and Measuring rate are shown here Battery life The testostor 171 series is equipped with long life L...

Page 14: ...ignal cricket sound be given off when limit values are exceeded Note the relay in testostor 1722 is activated once the limit values are determined in the probe configuration See page 23 The connected...

Page 15: ...me consuming settings START STOP This button starts and stops measurements which were programmed in the Remote controlled starting criteria Every measurement can be stopped via the stop button Descrip...

Page 16: ...tostor 171 2 171 3 0554 0640 Teflon sintered filter suitable for measurements in corrosive substances for 0636 9717 0554 0756 Teflon sintered filter suitable for measurements in corrosive substances t...

Page 17: ...P Tel 19 37 31 58 00 Fax 19 37 31 58 19 testo testo com br BULGARIA Global Test OOD 1408 Sofia Tel 2 9 53 07 96 Fax 2 9 52 51 95 glbl_tst sps bg CHILE ANWO S A Santiago Tel 2 7 31 00 00 Fax 2 2 73 04...

Page 18: ...95 20 Fax 93 753 95 26 info testo es SWEDEN Nordtec Instrument 40241 G teborg Tel 31 704 10 70 Fax 31 12 50 42 nordtec nordtec se SWITZERLAND Testo AG 8604 Volketswil Tel 1 9 08 40 50 Fax 1 9 08 40 5...

Page 19: ...0971 2530 T Ni PC_qxd 08 02 Testo AG Postfach 11 40 D 79849 Lenzkirch Testo Stra e 1 D 79853 Lenzkirch Tel 0 76 53 6 81 0 Fax 0 76 53 6 81 1 00 E Mail info testo de http www testo de...

Reviews: