TESUP MASTER 940 (MADE IN EUROPE)
~ 28 ~
TESUP
TROUBLESHOOTING DETAIL
Error
Possible cause
Possible actions
Wind turbine
does not start up
Not enough wind
None
“Stop” switch pressed
Release the “Stop” switch
Rotor turns too
slowly
Rotor blades incorrectly attached
Attach the rotor blades
correctly
Rotor blades not balanced
Balance the rotor blades
Bearing for wind alignment is stiff
Replace the bearing
Generator makes contact as it
turns
Send the generator in to the
manufacturer
Unfavourable location or tower
too low
Check and move to another
location if necessary
Increase the height of the tower
Wind turbine
vibrates on
tower
Rotor not balanced
Balance the rotor
Tower not aligned vertically
Align the tower vertically
Tower bends in the wind
Design a more robust tower
Tower foundation has too much
clearance
Reduce the clearance to a
minimum
Wind turbine
system produces
too little power
Wind turbine or charge controller
defective
Contact the manufacturer or a
specialist dealer
Battery defective
Replace the battery
Battery too small
Use a larger battery (at least
100 Ah)
Battery fuse tripped
Replace the fuse
Check the electrical
connections
Cable cross-section does not
match installed cable length
Match the cable cross section
correctly
11.
TROUBLESHOOTING & DIAGNOSTICS
NOTE: Error messages are displayed on the TESUP charge controller.
Refer to the separate instructions
.
NOTE: Make a note of the relevant parameters at the site and have them
handy when you contact the manufacturer / specialist dealer.
Summary of Contents for MASTER 940
Page 2: ...TESUP MASTER 940 MADE IN EUROPE 2 TESUP A GLIMPSE OF MASTER 940 ...
Page 12: ...TESUP MASTER 940 MADE IN EUROPE 12 TESUP 4 1 1 POWER CURVE POWER CURVE ...
Page 13: ...TESUP MASTER 940 MADE IN EUROPE 13 TESUP 4 2 GENERAL ARRANGEMENT DRAWING ...
Page 21: ...TESUP MASTER 940 MADE IN EUROPE 21 TESUP ASSEMBLY PROCEDURE ...
Page 30: ...TESUP MASTER 940 MADE IN EUROPE 30 TESUP 13 DECLARATION ...
Page 33: ...TESUP MASTER 940 MADE IN EUROPE 33 TESUP 16 NOTES ...