Operation and Storage Manual of Panel Heater
Delay start function
The delay start function allows the user to set the time at which the convector will
switch on and start heating.
Activation and deactivation of Delay start function - /Quick start B2/
When the set time has elapse, the appliance going to Heating mode!
Initially a setting of 12 hours is set by default
If any of
or
buttons is held for more than 0.5 seconds, the time and
temperature settings start automatically increase or decrease at a rate of 4
units per second. Confirm with “Mode” button
or don’t press any button
for 3 seconds.
If user enters time – 00, this mode will not be implemented. If the “Delay start”
mode is already enabled and user selects the “Delay Start” mode again, it can
be changed the remaining time in both possible directions. You can exit this
mode by pushing the “On/Off”
button. Then panel heater will go into
“Heating” mode. The “Delay start” needs to be set from 0 to 96 hours.
Anti-frost mode
If the room temperature falls below 5°C and the panel heater is off, the heater
will turn on automatically in order to prevent freezing of the area. Indication –
in left top corner - only when work the anti-frost mode
Factory settings of the function is ON (switched On).
Activation and deactivation of Anti-frost mode
/Quick start B3/
“Temperature correction for the sensor” function
Due to the specifics of the temperature profile in some premises there may
be difference from the temperature shown on the display and the actually
measured temperature in the various locations of the heating appliance in the
room.
• See the temperature shown on the display of the appliance
• Measure the temperature at a place where the temperature is
“comfortable” enough for you (usually at a height of 60 cm from the floor,
in sitting positon). If you find a difference within a range of ±4°С, you can
set the necessary correction in the convector’s menu (It is important to
note that this function can be set only after the temperature has become
the same all around the room, and depending on the room type, the
minimum required time is 7 hours) by entering the temperature difference
resulting between the value on the display and the actually measured
temperature.
Note:
This function is used with the purpose of providing better temperature
comfort and energy saving for the user of the electric convector in the room
which it is in. A temperature difference greater than ±4 °C from the measured
temperature in a specific location in the room indicates that the room where you
use the convector in is not well insulated or the temperature is not the same all
around the room.
Example
: a convector in a room on a stone floor – the convector displays 18°С
(the set temperature is 22°С), the actually measured temperature (feeling of
reached comfort temperature) is 22°С at a height of 60 cm from the floor - > in
this case the convector continues to overheat the room (this is a direct energy
loss, but the convector cannot reach the set temperature because it measures the
temperature at a low height close to the floor) and it will never switch off. In this
case a temperature correction of +4°С needs to be applied to the sensor, thus the
convector will display 22°С and it will start switching off, and eventually it will
maintain the set temperature of 22°С).
The normal status of the function is 0°C by default
Activation and deactivation of Temperature correction - /Quick start B4/
If the factory reset function is used, the temperature correction has to be set
again. The factory setting of its value is 0°C.
Function Adaptive start
Adaptive start is a function which predicts and initiates the optimal start of
heating in order to reach the set-point temperature at the desired time;
Test according to user instruction / documentation. The function is tested in a room
with a continuous heat demand of 50 - 60% with reference to the wattage of the
test device. The product is working at a comfort temperature 23°C ± 3°C setpoint
until stable conditions. This temperature is the reference comfort temperature “Ct”.
Activate a set-back period of 7h +2h/-0h per 24h with a set-back of 4°C ± 1°C . The
comfort period being 17 -2h/+0h hours. With the adaptive control activated - let
the heater thermostat working during 4 periods (4 x 24 hours) of comfort and low
setback cycles. After the latest low setback period finishes the comfort temperature
“Ct” should be reached within ± 30 minutes deviation to the time target - with a
maximal difference of ± 1⁰C from the reference comfort temperature “Ct”.
- Factory settings of the function is ‘’ON”
Activation and deactivation of Adaptive start - /Quick start B5/
RESET to default settings
If the customer wants reset the convector to factory settings.
Visualization on Display in “RESET” settings /Quick start B6/
After using the reset function, the following functions will be re-set:
- clock time
- temperature correction value 0⁰C
- function Anti-frost mode is activated
- adaptive start is activated
- weekly program – 24/7 is reset.
Open window/door function
Room temperature control with open window detection - the product is
equipped with an integrated electronic device that reduces the heat output
when detects an open window or door. A sensor is used to detect eventual
drop in the room temperature. If the temperature falls more than 5˚C, the
convector will switch off by itself. Within 15 min the open window detection
should turn the appliance off. When the room temperature rises by at least
0.5°C and the difference from the initial set point is below 5°C, the convector
switches itself on with the settings already made. If the temperature does
not rise for more than 60 minutes, the convector enters Standby mode. The
function is allowed to be cancelled manually.
The function can be switched Off manually.
Activation and deactivation of
Open window/door function
- /Quick start
B8/
Note:
When the “Open window” function is enabled, the “Anti-frost” function
does not work!
Keyboard lock (Protection from children)
When user turns on this function, all keys of the control panel remain locked.
Activation and deactivation of
Keyboard lock
- /Quick start B7/
Day and time – settings
/Quick start B9/
First step or use after factory reset function
Weekly program (timer) 24hours/7days
Min 300 sets of time periods
Electronic thermoregulator with weekly program (timer) 24/7 - electronic room
temperature control plus weekly timer means the product is equipped with
an electronic device, either integrated or external, which allows the product
automatically to vary its heat output over a certain time period. In relation
with a certain required level of indoor heating comfort. It allows the setting
of timing and temperature levels for a full week. During the 7-day period the
settings must allow a variation on a day-to-day basis;
Activation and deactivation of Weekly program - /Quick start B10/
There have three options
/Quick start B10/
:
- CREATE PROGRAM
- ERASE PROGRAM
- VIEW PROGRAM
The temperature of 22 ˚C started at 12.30 to 15.00 on Sunday. The convector
will heat till reach the settings of the next given point.
If the TIME PERIOD is empty (no time set) – visualization should be