TABLE 2: INFORMATION REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS
Model identifier(s):
1.CN 052 200 EI CLOUD W F 230V~ 50Hz
Ite
m
Symbol
Value 1
Unit
Ite
m
Unit
Heat output
Type of heat input for electric storage local space heaters only (select one)
Nominal heat output
P
nom
2.00
kW
Manual heat charge control, with integrated thermostat
[no]
Minimum heat output (indicative)
P
min
0.00
kW
Manual heat charge control, with room and/or outdoor temperature feedback
[no]
Maximum continuous heat output
(indicative)
P
max,C
2.00
kW
Electric heat charge control, with room and/or outdoor temperature feedback heat charge control,
with integrated thermostat
[no]
Auxiliary electricity consumption
Fan assisted heat output
[no]
At nominal heat output
el
max
1.91
kW
Type of heat output/room temperature control (select one)
-
At minimum heat output
el
min
0.00
kW
Single stage heat output and no room temperature control
[no]
In standby mode
el SB
0.00054
kW
Two or more manual stages, no room temperature control
[no]
With mechanic thermostat room temperature control
[no]
With electronic room temperature control
[no]
With electronic room temperature control plus day timer
[no]
With electronic room temperature control plus week timer
[yes]
Other control options (multiple selections possible)
Room temperature control, with presence detection
[no]
Room temperature control, with open window detection
[yes]
With distance control option
[no]
With adaptive start control
[yes]
With working time limitation
[no]
With black bulb sensor
[no]