7. External programming 
 

The output voltage, current and OV protection can be adjusted externally with programming voltages. 
The voltage and current can also be adjusted by means of resistance programming. 

 
 
7.1 External voltage programming 
 

The programming voltage source is connected with its minus lead to TB4-8 and its plus lead to 
TB4-15. To activate the external mode the switch ‘‘EXTERN’’ is pushed. The yellow LED 
indicatior illuminates if the external mode is active. 
The programming voltage may have values between 0 and + 10V. The output voltage is linear 
and proportional to the programming voltage. 
The load for the auxiliary source is 150µA. 
 
NOTE 
 
1. When the programming line is interrupted during operation, the output voltage drops to zero. 
 
2. When using long programming leads it is recommended to use shielded cable in order to 
prevent external distortions. It is also recommended to apply accordingly blocking capacitors to 
the terminals in case of oscillation due to the inductivity of long programming leads. 
 
3. Ripple, stability and Tc of ARGOS depends on the auxiliary source specifications. 
 
 

7.2 RVP (Resistance Voltage Programming) 
 

The output voltage can be externally programmed using a 0 to 10 kOhm resistance. The 
configuration is shown here under. 

 
TB3-8 

 

Rprog 
0...10kOhm

TB3-14 

 

TB3-15 
 

The output of the power supply is : 
Vout = (Rprog/10) x Vmax Rprog in kOhm; Vout, Vmax in volt 
 
NOTE: 
 
a) In order to prevent stability fault it is recommended to use oversized resistors (eg. 2W) with a 
Tc of <=20ppm/¦C. 
 
b) During RVP mode the sliding switch S1 on the rear panel must be positioned on the right side 
and the ‘‘EXTERN’’ switch on the frontpanel in the position INTERN (not pushed). 
 
c) With Rprog = 12kOhm will Vout = 1.2xVmax 
 
d) In case Rprog>20kOhm (interruption), the output voltage is programmed to zero. 
 
e) RVP and Tracking modes are effective simultaneously. The output voltage always results 
from the highest programmed value. If no voltage is on TB3-5 (TRACKING) the RVP mode is 
not influenced by the tracking mode (see Tracking mode). 
 
f) When the sliding switch S1 is in the left position the output voltage is adjusted with the control 
on the frontpanel. In this case Rprog has to be removed. 
 
 

Argos 1200 
     Page 

von 

16 

   ISSUE 

07/05 

Summary of Contents for Argos 100-12

Page 1: ...eAlpine Allee 1 D 94513 Sch nberg Tel 49 0 85 54 9609 0 Fax 49 0 85 54 96 09 20 Mail sales tetelectronics de INSTRUCTION MANUAL ARGOS 1200 High performance power supplies Argos 1200 Page 1 von 16 ISSU...

Page 2: ...current limiting 5 Constant current operation with voltage limiting 6 Sensing compensation 7 External programming 8 Overvoltage protection 9 Serial mode 10 Parallel mode 11 Tracking 12 Monitor and St...

Page 3: ...ent adjustable with a 10 turn potentiometer Regulation accuracy LINE 0 01 by 10 line fluctuation LOAD 0 1 from full load to short circuit Temperature coefficient 0 01 K measured in a range of 0 50 C 1...

Page 4: ...ent control 10 turn pot 6 External internal switch and External LED indicator 7 Remote enable indicator 8 LED indicator for constant voltage mode 9 LED indicator for constant current mode 10 Adjustmen...

Page 5: ...nbuchse S1 S2 Fig 2 1 Power supply rearpanel 2 Load terminals 3 AC input and main fuse TB1 4 Terminal block for sense line and output voltage V V TB2 5 Opt 34 IEEE bus interface connector address swit...

Page 6: ...TB 4 15 U PROG Setting and Function see chapter 7 2 and 7 4 TB 3 PIN LAYOUT 15 Pin Sub D connector RVP TRACKIG TB3 TB4 ON OFF ON OFF TB 3 1 SLAVE TB 3 2 MASTER TB 3 3 RCP TB 3 4 10V REF TB 3 5 TRACKIN...

Page 7: ...g the current control knob CURRENT The lower limit for the constant current operation is 100mA It is important to be careful particularly when working with small output currents since the charging or...

Page 8: ...mming leads 3 Ripple stability and Tc of ARGOS depends on the auxiliary source specifications 7 2 RVP Resistance Voltage Programming The output voltage can be externally programmed using a 0 to 10 kOh...

Page 9: ...n due to the inductivity of long programming leads 3 Ripple stability and Tc of ARGOS depends on the auxiliary source specifications 7 4 RCP Resistance Current Programming The output current can be pr...

Page 10: ...the auxiliary source is 250 A 7 6 If only one output parameter is to be programmed it is possible to adjust the non programmed parameter to the maximum value In order to achieve this the non programme...

Page 11: ...auxiliary voltage corresponding to the desired threshold is to be applied on the load terminal 8 2 OV RESET After an activation of the overvoltage circuit it remains triggered until a RESET signal oc...

Page 12: ...al to ARGOS 1 V load terminal cross section 5A mm 2 4 ARGOS 2 S to plus pole of load 2 5 ARGOS 2 S to ARGOS 1 S 2 6 ARGOS 1 S to minus pole of load The output voltages are adjusted via the correspondi...

Page 13: ...ecause it is not possible to ensure a simultaneously switch off of the devices in case of an over voltage decoupling diodes should be used In that case a sensing compensation is not possible see also...

Page 14: ...on 2 9 TB 4 15 of first slave to TB 3 4 of first slave This one do for all slaves again 3 Please note 3 1 All ARGOS power supplies have to be switched on and off simultaneously 3 2 In view of the stab...

Page 15: ...tor R1 should be oversized eg 2W with a Tc of 20ppm C NOTE a In tracking mode the slave ARGOS is to be set in RVP mode S1 right EXTERN not pushed However a programming resistor is not connected conseq...

Page 16: ...Simultaneously the output power is slowly diminished During this state only the MOSFET s temperature approx 85 C is regulated The LED indicators CV and CC do not light up as ARGOS under such condition...

Reviews: