TPMC533 User Manual Issue 1.0.1
Page 44 of 107
Bit
Symbol
Description
Access
Reset
Value
0
OU_ENA
Output Unit Enable
0: Output Unit Disabled
1: Output Unit Enabled
Enables the Output Unit.
The Output Unit handles the DAC Data transfer from the
Sequencer's internal FIFO to the DACs and the DAC
Sequencer's Conversion Rate generation.
While the DACs operating in Sequencer Mode are not
completely pre-loaded with DAC Data, these values are
automatically transferred from the FIFO to the DACs'
internal registers to pre-load them for the first/next
conversion (except in an error case).
The Output Unit operation is stopped in case of an Output
Unit Error. In this case the DAC Sequencer Status Register
must be read and the Output Unit can be disabled.
The Output Unit is reset when disabled.
R/W
0
Table 3-42: DAC Sequencer Control Register