UNPACKING AND ASSEMBLY
11
Danger
: Do not detach or cut the aluminium blades that
seal the 6 bottle elements.
Danger
:
To start the battery, the operator must:
1)
Take the battery out of the box and rest it on a sturdy
surface. Take off the multiple cap closing the 6 elements
2)
Position the bottle of electrolytic liquid above the battery
holes
being careful to keep it in
“vertical” position.
DO NOT
hold it at an angle
Press the bottle so the special electrolytic
fluid introduction tubes, (present on the
battery), perforate the sealed tangs of the
bottle and thus allow
the fluid to flow from the bottle into the battery. If necessary, lightly tap
the bottle to allow the fluid to flow into the six elements
Wait for all the liquid to flow into the battery before detaching the
bottle
3)
Replace the multiple cap and press it well down
Danger
: Never open the caps.
Danger
: Never add any more electrolytic fluid.
Danger
: Never overturn the battery.
Danger
: Never throw the battery away into the
environment. If the battery has to be changed, follow the
disposal procedures laid down by local authorities
4)
Fit the battery in its housing.
IMPORTANT
Position the
battery with the
polarities
(
+
)
and
(
—
)
5)
Connect the battery
connectors to the machine
connection leads and tighten the 2
screws. then cover the
protective
cap for the 2 wire is in place.
6)
Secure the battery with the
small rubber and bolt.
IMPORTANT Use the battery after 30 minutes from
filling with electrolytic fluid.