6.
To actuate press, depress both black pushbuttons labeled “Start Cycle” located on the
sides of the machine simultaneously. When press cycle is in progress, the amber light
on the control panel will turn on and remain on for all but the last two seconds of the
timing cycle. At that time the amber light will go into a blinking mode to alert the
operator that the press cycle is nearly complete.
7.
To immediately open the press, push the red “Emergency Release” pushbutton located
on the upper left side of the control panel. Also, the press should open immediately if
the power switch is turned “OFF” or if the machine power cord is unplugged.
CONVERSION TABLE
GAUGE
PRESSURE
TOTAL INTER-
PLATEN
PRESSURE
LBS. PSI 2” x
4” PLATEN
LBS. PSI 3” x
5” PLATEN
LBS. PSI 4” x
6” PLATEN
LBS. PSI 5” x
6” PLATEN
LBS. PSI 3 ¼” x
5” EXTENDED
ANVIL PLATEN
25
177
22.1
11.8
7.4
5.9
10.9
30
212
26.5
14.1
8.8
7.1
13.0
35
247
30.9
16.5
10.3
8.2
15.2
40
283
35.4
18.9
11.8
9.4
17.4
45
318
39.8
21.2
13.2
10.6
19.6
50
353
44.1
23.5
14.7
11.8
21.7
55
389
48.6
25.9
16.2
13.0
23.9
60
424
53.0
28.3
17.7
14.1
26.1
65
459
57.4
30.6
19.1
15.3
28.2
70
495
61.9
33.0
20.6
16.5
30.5
75
530
66.2
35.3
22.1
17.7
32.6
80
565
70.6
37.7
23.5
18.8
34.8
85
601
75.1
40.1
25.0
20.0
37.0
90
636
79.5
42.4
26.5
21.2
39.1
95
672
84.0
44.8
28.0
22.4
41.4
100
707
88.4
47.1
29.5
23.6
43.5
105
742
92.7
49.5
30.9
24.7
45.7
110
778
97.2
51.9
32.4
25.9
47.9
115
813
101.6
54.2
33.9
27.1
50.0
120
848
106.0
56.5
35.3
28.3
52.2
Table A-1
Maintenance
Drain moisture trap on Air Filter / Regulator as often as necessary.
Check sponge and teflon. Replace if needed.