Requirements
1.
Air – 25 PSI minimum / 120 PSI maximum
2.
Electrical Requirements – 240v A.C. / 60 Cycle
POWER CONSUMPTION
PLATEN SIZE
WATTS
AMPS
2” x 4”
900
4
3” x 5”
1200
5
4” x 6”
1320
5.5
5” x 6”
1800
7.5
3 ¼” x 5” Extended Anvil
660
3
Installation
1.
Bolt base of machine securely in desires place and position.
2.
Connect air supply to 1/8” Female NPT fitting located in the back at the base of the
machine.
3.
Plug in electrical cord to properly fused and grounded receptacle.
Operation
1.
Set the Air Regulator located on the right side of the swivel head at the required gauge
pressure: 25 PSI minimum / 120 PSI maximum. To adjust regulator, pull up and turn black
knob. Clockwise increases pressure, counter-clockwise decreases pressure. When pressure
is set, push down black knob to lock. See
table A-1
to convert gauge pressure to total
interplaten pressure and pounds of pressure per square inch on platen surface.
2.
Check Air Filter Bowl located beneath Air Regulator and Gauge. If water is visible in bowl,
drain moisture by turning shaft, located on the bottom of the bowl, counter-clockwise.
3.
Flip power switch located on the lower left side of the swivel head to “ON”. Green light on
control panel indicates the power is “ON”.
4.
Set individual platen temperature with the corresponding control knobs located on the
control panel to desired temperature setting. Allow 10 minutes for platens to heat up.
While platens are heating their corresponding red light on the control panel will remain on.
When platens reach desired temperature the red light will turn off momentarily. As the
temperature controllers phase on and off to maintain desired platen temperature, the red
lights will phase on and off also. Platen heat can be turned off individually by turning knob
counter-clockwise until it clicks.
5.
Set Timer Control located on upper left of control panel to desired cycle dwell time. This
time setting will repeat each press cycle until changed.