background image

 

Requirements

 

 

1.

 

Air – 25 PSI minimum / 120 PSI maximum 

2.

 

Electrical Requirements – 240v A.C. / 60 Cycle 

 

POWER CONSUMPTION 

PLATEN SIZE 

WATTS 

AMPS 

2” x 4” 

900 

3” x 5” 

1200 

4” x 6” 

1320 

5.5 

5” x 6” 

1800 

7.5 

3 ¼” x 5”   Extended Anvil 

660 

 
 

Installation 

 

1.

 

Bolt base of machine securely in desires place and position. 

2.

 

Connect air supply to 1/8” Female NPT fitting located in the back at the base of the 
machine. 

3.

 

Plug in electrical cord to properly fused and grounded receptacle. 

 
 

Operation 

 

1.

 

Set the Air Regulator located on the right side of the swivel head at the required gauge 
pressure: 25 PSI minimum / 120 PSI maximum.  To adjust regulator, pull up and turn black 
knob.  Clockwise increases pressure, counter-clockwise decreases pressure.  When pressure 
is set, push down black knob to lock.  See 

table A-1

 to convert gauge pressure to total 

interplaten pressure and pounds of pressure per square inch on platen surface. 

2.

 

Check Air Filter Bowl located beneath Air Regulator and Gauge.  If water is visible in bowl, 
drain moisture by turning shaft, located on the bottom of the bowl, counter-clockwise. 

3.

 

Flip power switch located on the lower left side of the swivel head to “ON”.  Green light on 
control panel indicates the power is “ON”. 

4.

 

Set individual platen temperature with the corresponding control knobs located on the 
control panel to desired temperature setting.  Allow 10 minutes for platens to heat up.  
While platens are heating their corresponding red light on the control panel will remain on.  
When platens reach desired temperature the red light will turn off momentarily.  As the 
temperature controllers phase on and off to maintain desired platen temperature, the red 
lights will phase on and off also.  Platen heat can be turned off individually by turning knob 
counter-clockwise until it clicks. 

5.

 

Set Timer Control located on upper left of control panel to desired cycle dwell time.  This 
time setting will repeat each press cycle until changed. 

Reviews: