background image

 
 

 

 

 

SNAU120-April 2012 

 

 

 

 

 

 

 

ADC161S626BEB User’s Guide 

 

 

 

 

  

 

 

EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS 

 

Texas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions: 
 
The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user 
indemnifies TI from all claims arising from the handling or use of the goods. 
 
Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/ kit may be 
returned within 30 days from the date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE 
EXCLUSIVE WARRANTY MADE BY SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, 
EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS 
FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, 
NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR 
CONSEQUENTIAL DAMAGES. 
 
Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to 
handling the product. This notice contains important safety information about temperatures and voltages. For 
additional information on TI's environmental and/or safety programs, please visit 

www.ti.com/esh

 or contact TI. 

 
No license is granted under any patent right or other intellectual property right of TI covering or relating to any 
machine, process, or combination in which such TI products or services might be or are used. TI currently deals 
with a variety of customers for products, and therefore our arrangement with the user is not exclusive. TI assumes 
no liability for applications assistance, customer product design, software performance, or infringement of patents 
or services described herein. 
 
 

Mailing Address: Texas Instruments Post Office Box 655303 Dallas, Texas 75265 

 

Copyright 2012, Texas Instruments Incorporated 

 

 
 

REGULATORY COMPLIANCE INFORMATION 

 
 

As noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be 
subject to the Federal Communications Commission (FCC) and Industry Canada (IC) rules. 
 
For EVMs 

not

 subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING 

DEVELOPMENT, DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a 
finished end product fit for general consumer use. It generates, uses, and can radiate radio frequency energy and 
has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC or ICES-003 
rules, which are designed to provide reasonable protection against radio frequency interference.  Operation of the 
equipment may cause interference with radio communications, in which case the user at his own expense will be 
required to take whatever measures may be required to correct this interference. 
 

General Statement for EVMs including a radio 

 
User Power/Frequency Use Obligations:  This radio is intended for development/professional use only in legally 
allocated frequency and power limits.  Any use of radio frequencies and/or power availability of this EVM and its 
development application(s) must comply with local laws governing radio spectrum allocation and power limits for 
this evaluation module.  It is the user’s sole responsibility to only operate this radio in legally acceptable frequency 
space and within legally mandated power limitations.  Any exceptions to this is strictly prohibited and unauthorized 
by Texas Instruments unless user has obtained appropriate experimental/development licenses from local 
regulatory authorities, which is responsibility of user including its acceptable authorization. 

 

Summary of Contents for ADC161S626BEB

Page 1: ...ase evaluation of the ADC161S626 With the optional SPIO4 board and optional Sensor board the board allows evaluation of an entire Sensor AFE system The evaluation board can be used in stand alone mode in which the user interfaces with the part through the SPIO GPSI16 connector and applies input signals on the AB12 connector The board can also be used with an SPIO4 board in place of an external pat...

Page 2: ...the SPIO4 board GPSI16 16 pin dual row right angle female header Carries signals from the SPIO4 board to any optional SensorAFE board AB12 12 pin dual row right angle male header Carries analog bus signals from an external source or the optional Sensor AFE board to the ADC Table 2 Connectors on the ADC161S626 Evaluation Board Jumper Purpose VREF SELECT Selects reference source for VREF Settings ar...

Page 3: ... This will connect the ADC VREF line to the 4 096V on board LM4120 reference Ensure that a 4MHz crystal is installed in the socket Y2 and that there is no signal applied at the CLK IN BNC jack Connect the SPIO4 board to the ADC161S626BEB board at the SPIO GSPI16 male header Line up the white arrows on the bottom of the headers Connect the LMP91000 board to the GPSI16 and AB12 headers Line up the w...

Page 4: ...to generate a clock for the SPIO4 board o Bring a clock to the SPIO GPSI16 header from an external board of your choice 4 Functional Description 4 1 ADC Reference Circuitry This evaluation board includes three options to source the voltage reference VREF The options are selecting the fixed on board 4 096V voltage reference LM4120 4 1 to source VREF connecting VREF to VA of the device or using the ...

Page 5: ...SNAU120 April 2012 ADC161S626BEB User s Guide 5 5 Hardware Schematic ...

Page 6: ...PIO GPSI16 Header 8 Pin Dual row Right Angle Sullins Connector Solutions PBC36DGAN 2 9 VA SELECT Header TH 100mil 1x2 Gold plated 230 mil above insulator Samtec Inc TSW 102 07 G S 1 10 VIO SELECT VREF SELECT Header TH 100mil 1x3 Gold plated 230 mil above insulator Samtec Inc TSW 103 07 G S 2 11 U6 IC EEPROM 2KBIT 400KHZ 8TSSOP ON Semiconductor CAT24C01WI GT3 1 12 Y2 OSC 4 000 MHZ 5 0V FULL SIZE EC...

Page 7: ...gement of patents or services described herein Mailing Address Texas Instruments Post Office Box 655303 Dallas Texas 75265 Copyright 2012 Texas Instruments Incorporated REGULATORY COMPLIANCE INFORMATION As noted in the EVM User s Guide and or EVM itself this EVM and or accompanying hardware may or may not be subject to the Federal Communications Commission FCC and Industry Canada IC rules For EVMs...

Page 8: ...armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televi...

Page 9: ... de brouillage radioélectrique à l intention des autres utilisateurs il faut choisir le type d antenne et son gain de sorte que la puissance isotrope rayonnée équivalente p i r e ne dépasse pas l intensité nécessaire à l établissement d une communication satisfaisante Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d antenne énumérés dans le manuel d u...

Page 10: ...技術基準適合証明を受けておりません 本製品のご使用に際しては 電波法遵守のため 以下のいずれかの措置を取っていただく必要がありますのでご注 意ください 1 電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗 室等の試験設備でご使用いただく 2 実験局の免許を取得後ご使用いただく 3 技術基準適合証明を取得後ご使用いただく なお 本製品は 上記の ご使用にあたっての注意 を譲渡先 移転先に通知しない限り 譲渡 移転できないも のとします 上記を遵守頂けない場合は 電波法の罰則が適用される可能性があることをご留意ください 日本テキサス インスツルメンツ株式会社 東京都新宿区西新宿6丁目24番1号 西新宿三井ビル http www tij co jp ...

Page 11: ... limited to input and output voltage current power and environmental ranges may cause property damage personal injury or death If there are questions concerning these ratings please contact a TI field representative prior to connecting interface electronics including input power and intended loads Any loads applied outside of the specified output range may result in unintended and or inaccurate op...

Page 12: ...warranties for the associated TI product or service and is an unfair and deceptive business practice TI is not responsible or liable for any such statements TI products are not authorized for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parties have executed an...

Page 13: ...SNAU120 April 2012 ADC161S626BEB User s Guide 13 Mailing Address Texas Instruments Post Office Box 655303 Dallas Texas 75265 Copyright 2007 Texas Instruments Incorporated ...

Reviews: