IOUT =1.0 mA
COMP=1.2 V
Keithley 2420
120mF
Test and Measurment Summary
Charging a Super Capacitor from Buck Converter Output
The test setup is shown in
. The specific equipment used for the test results in
is listed
below:
1. VIN_DC was connected to a Keithley 2420 source-meter configured as a 1.0-mA current source with
1.2-V voltage compliance.
2. VOUT was connected to a 120 mF super capacitor. There were no other loads on VSTOR, VBAT or
VOUT.
3. VIN_DC, VSTOR and VOUT were measured with oscilloscope voltage probes connected at TP1, TP4
and TP6.
Figure 11. Test Setup for Charging a Super Capacitor from Buck Output
Figure 12. Charging a Super Cap from V
OUT
The benefit of charging of the super capacitor on VOUT instead of VBAT is faster charge time due to the
charger spending less time in less efficient cold start mode.
Tips for other Tests and Measurements
15
SLUUAA7A – July 2013 – Revised August 2014
User's Guide for bq25570 Battery Charger Evaluation Module for Energy
Harvesting
Copyright © 2013–2014, Texas Instruments Incorporated