Table 14-1. Data Flash Table (continued)
Class
Subclass
Address
Name
Type
Min Value
Max Value
Default
Units
Advanced Charge
Algorithm
Cell Balancing
Config
0x4708
Bal Time/mAh Cell 2
U2
0
65535
361
s/mAh
Advanced Charge
Algorithm
Cell Balancing
Config
0x470A
Min Start Balance Delta
U1
0
255
3
mV
Advanced Charge
Algorithm
Cell Balancing
Config
0x470B
Relax Balance Interval
U4
0
429496729
5
18000
s
Advanced Charge
Algorithm
Cell Balancing
Config
0x470F
Min Rsoc for Balancing
U1
0
100
80
%
Gas Gauging
Current Thresholds
0x46A1
Dsg Current Threshold
I2
–32768
32767
100
mA
Gas Gauging
Current Thresholds
0x46A3
Chg Current Threshold
I2
–32768
32767
50
mA
Gas Gauging
Current Thresholds
0x46A5
Quit Current
I2
0
32767
10
mA
Gas Gauging
Current Thresholds
0x46A7
Dsg Relax Time
U1
0
255
1
s
Gas Gauging
Current Thresholds
0x46A8
Chg Relax Time
U1
0
255
60
s
Gas Gauging
Standby
0x4618
StandbyCurrent
I2
–32768
0
–10
mA
Gas Gauging
Max Load
0x461A
Max Load Current
I2
–32768
0
–500
mA
Gas Gauging
Max Load
0x461C
Max Load Rsoc
U1
0
100
50
%
Gas Gauging
Design
0x4625
Design Capacity mAh
I2
0
32767
4400
mAh
Gas Gauging
Design
0x4627
Design Capacity cWh
I2
0
32767
6336
cWh
Gas Gauging
Design
0x4629
Design Voltage
I2
0
32767
7200
mV
Gas Gauging
Cycle
0x462B
Cycle Count Percentage
U1
0
100
90
%
Gas Gauging
FD
0x4630
Set Voltage Threshold
I2
0
5000
3000
mV
Gas Gauging
FD
0x4632
Clear Voltage Threshold
I2
0
5000
3100
mV
Gas Gauging
FD
0x4634
Set % RSOC Threshold
U1
0
100
0
%
Gas Gauging
FD
0x4635
Clear % RSOC Threshold
U1
0
100
5
%
Gas Gauging
FC
0x4636
Set Voltage Threshold
I2
0
5000
4200
mV
Gas Gauging
FC
0x4638
Clear Voltage Threshold
I2
0
5000
4100
mV
Gas Gauging
FC
0x463A
Set % RSOC Threshold
U1
0
100
100
%
Gas Gauging
FC
0x463B
Clear % RSOC Threshold
U1
0
100
95
%
Gas Gauging
TD
0x463C
Set Voltage Threshold
I2
0
5000
3200
mV
Gas Gauging
TD
0x463E
Clear Voltage Threshold
I2
0
5000
3300
mV
Gas Gauging
TD
0x4640
Set % RSOC Threshold
U1
0
100
6
%
Gas Gauging
TD
0x4641
Clear % RSOC Threshold
U1
0
100
8
%
Gas Gauging
TC
0x4642
Set Voltage Threshold
I2
0
5000
4200
mV
Gas Gauging
TC
0x4644
Clear Voltage Threshold
I2
0
5000
4100
mV
Gas Gauging
TC
0x4646
Set % RSOC Threshold
U1
0
100
100
%
Gas Gauging
TC
0x4647
Clear % RSOC Threshold
U1
0
100
95
%
Gas Gauging
State
0x4206
Qmax Cell 1
I2
0
32767
4400
mAh
Gas Gauging
State
0x4208
Qmax Cell 2
I2
0
32767
4400
mAh
Gas Gauging
State
0x420A
Qmax Pack
I2
0
32767
4400
mAh
Gas Gauging
State
0x420C
Qmax Cycle Count
U2
0
65535
0
—
Gas Gauging
State
0x420E
Update Status
H1
0x0
0x0E
0x0
—
Gas Gauging
State
0x420F
Cell 1 Chg Voltage at EoC
I2
0
32767
4200
mV
Gas Gauging
State
0x4211
Cell 2 Chg Voltage at EoC
I2
0
32767
4200
mV
Gas Gauging
State
0x4213
Current at EoC
I2
0
32767
250
mA
Gas Gauging
State
0x4215
Avg I Last Run
I2
–32768
32767
–2000
mA
Gas Gauging
State
0x4217
Avg P Last Run
I2
–32768
32767
–3022
cW
Gas Gauging
State
0x4219
Delta Voltage
I2
–32768
32767
0
mV
Gas Gauging
State
0x421B
Temp k
I2
0
32767
100
0.1°C/256
cW
Gas Gauging
State
0x421D
Temp a
I2
0
32767
1000
s
Gas Gauging
State
0x421F
Max Avg I Last Run
I2
–32768
32767
–2000
mA
Data Flash Summary
SLUUCO0 – APRIL 2022
BQ28Z610-R2
123