13.4.7 Maintenance Charging
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Advanced
Charging
Algorithms
MCHG
Current
I2
0
32767
44
mA
Maintenance
ChargingCurrent()
13.4.8 Voltage Range
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Advanced
Charging
Algorithms
Voltage Range
Threshold for
entering
precharge state
I2
0
32767
2500
mV
Minimum Cell voltage to enter PRECHARGE
mode
Advanced
Charging
Algorithms
Voltage Range
Charging
Voltage Low
I2
0
32767
2900
mV
Precharge Voltage range to Charging Voltage
Low range
Advanced
Charging
Algorithms
Voltage Range
Charging
Voltage Med
I2
0
32767
3600
mV
Charging Voltage Low range to Charging Voltage
Med range
Advanced
Charging
Algorithms
Voltage Range
Charging
Voltage High
I2
0
32767
4000
mV
Charging Voltage Med to Charging Voltage High
range
Advanced
Charging
Algorithms
Voltage Range
Charging
Voltage
Hysteresis
U1
0
255
0
mV
Charging Voltage Hysteresis applied when
voltage is decreasing
13.4.9 Termination Config
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Advanced
Charging
Algorithms
Termination
Config
Charge Term
Taper Current
I2
0
32767
250
mA
Valid Charge Termination taper current qualifier
threshold
Advanced
Charging
Algorithms
Termination
Config
Charge Term
Voltage
I2
0
32767
75
mV
Valid Charge Termination delta voltage qualifier,
max cell based
13.4.10 Cell Balancing Config
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Advanced
Charging
Algorithms
Cell Balancing
Config
Balance Time
per mAh cell 1
U2
0
65535
367
s/mAh
Required balance time per mAh. For information
on how to calculate balancing time, see
.
Advanced
Charging
Algorithms
Cell Balancing
Config
Balance Time
per mAh cell 2
U2
0
65535
514
s/mAh
Required balance time per mAh. For information
on how to calculate balancing time, see
.
13.5 Power
13.5.1 Power
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Power
Power
Valid Update
Voltage
I2
0
32767
2800
mV
Min stack voltage threshold for Flash update
13.5.2 Shutdown
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Power
Shutdown
Shutdown
Voltage
I2
0
32767
2300
mV
Cell based shutdown voltage trip threshold
Power
Shutdown
Shutdown Time
U2
0
255
10
s
Cell based shutdown voltage trip delay
Power
Shutdown
Charger
Present
Threshold
I2
0
32767
3000
mV
Pack terminal charger present detect threshold
Data Flash Values
104
BQ28Z610-R2