Errors
36
SWRU455A – February 2017 – Revised March 2017
Copyright © 2017, Texas Instruments Incorporated
Device
lists common errors statuses.
Table 3-5. Common Error Codes
Error
Value
Comments
SL_ERROR_ROLE_STA_ERR
–4107
Initialization failure in the specified mode (sl_Start)
SL_ERROR_ROLE_AP_ERR
–4108
SL_ERROR_ROLE_P2P_ERR
–4108
SL_ERROR_CALIB_FAIL
–4110
Calibrations failed
SL_ERROR_FS_CORRUPTED_ERR
–4111
File system is corrupted, restore to factory image or
program new image should be invoked (see sl_FsCtl,
sl_FsProgram)
SL_ERROR_FS_ALERT_ERR
–4112
Initialization failure due to exceeded number of security
alerts (sl_Start); device is locked, restore to factory image
or program new image should be invoked (see sl_FsCtl,
sl_FsProgram)
SL_ERROR_RET_TO_IMAGE_COMLETE
–4113
Restore to factory image completed, perform reset
SL_ERROR_INCOMPLETE_PROGRAMMING
–4117
Error during programming. Program new image should be
invoked (see sl_FsProgram).
SL_ERROR_DEVICE_LOCKED_SECURITY_ALLERT
–28674
Number of security alerts exceeded or system file integrity
error; device is locked.