7.6.12 GENERAL-STATUS Register (address = 22h) [reset = 00h, DEVICE-ID, VERSION-ID]
PMBus page address = FFh, PMBus register address = E6h
Figure 7-33. GENERAL-STATUS Register
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
NVM-
CRC-
FAIL-INT
NVM-
CRC-
FAIL-
USER
X
DAC-0-
BUSY
X
DAC-1-
BUSY
X
DEVICE-ID
VERSION-ID
R-0h
R-0h
R-0h
R-0h
X-0h
R-0h
X-0h
R
R-0h
Table 7-36. GENERAL-STATUS Register Field Descriptions
Bit
Field
Type
Reset
Description
15
NVM-CRC-FAIL-INT
R
0
0: No CRC error in OTP
1: Indicates a failure in OTP loading. A software
reset or power-cycle can bring the device out of
this condition in case of temporary failure.
14
NVM-CRC-FAIL-USER
R
0
0: No CRC error in NVM loading
1: Indicates a failure in NVM loading. The register
settings are corrupted. The device allows all
operations during this error condition. Reprogram
the NVM to get original state. A software reset
brings the device out of this temporary error
condition.
13
X
R
0
Don't care
12
DAC-0-BUSY
R
0
0: DAC-0 channel can accept commands
1: DAC-0 channel does not accept commands
11-10
X
X
0
Don't care
9
DAC-1-BUSY
R
0
0: DAC-1 channel can accept commands
1: DAC-1 channel does not accept commands
8
X
R
0
Don't care
7-2
DEVICE-ID
R
DAC63002: 08h
DAC63001: 09h
DAC53002: 0Ah
DAC53001: 0Bh
Device identifier
1-0
VERSION-ID
R
00
Version identifier
DAC53001, DAC53002, DAC63001, DAC63002
SLASF48 – MAY 2022
Copyright © 2022 Texas Instruments Incorporated
65
Product Folder Links: