MSP430xG461x
MIXED SIGNAL MICROCONTROLLER
SLAS508I − APRIL 2006 − REVISED MARCH 2011
39
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
POR/brownout reset (BOR) (see Note 1)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
t
d(BOR)
2000
μ
s
V
CC(start)
dV
CC
/dt
≤
3 V/s (see Figure 10)
0.7
×
V
(B_IT−)
V
V
(B_IT−)
Brownout
dV
CC
/dt
≤
3 V/s (see Figure 10 through Figure 12)
1.79
V
V
hys(B_IT−)
(see Notes 2 and 3)
dV
CC
/dt
≤
3 V/s (see Figure 10)
70
130
210
mV
t
(reset)
Pulse length needed at RST/NMI pin to accepted reset
internally, V
CC
= 2.2 V/3 V
2
μ
s
NOTES:
1. The current consumption of the brownout module is already included in the I
CC
current consumption data.
2. The voltage level V
(B_IT−)
+ V
hys(B_IT−)
is
≤
1.89V.
3. During power up, the CPU begins code execution following a period of t
d(BOR)
after
V
CC
= V
(B_IT−)
+ V
hys(B_IT−)
. The default
FLL+ settings must not be changed until V
CC
≥
V
CC(min)
, where V
CC(min)
is the minimum supply voltage for the desired
operating frequency. See the MSP430x4xx Family User’s Guide for more information on the brownout/SVS circuit.
typical characteristics
0
1
t d(BOR)
VCC
V(B_IT−)
Vhys(B_IT−)
V
CC(start)
Figure 10. POR/Brownout Reset (BOR) vs Supply Voltage
VCC(drop)
VCC
3 V
t pw
0
0.5
1
1.5
2
0.001
1
1000
Typical Conditions
1 ns
1 ns
t
pw
− Pulse Width −
μ
s
t
pw
− Pulse Width −
μ
s
V
CC
= 3 V
V
CC(drop)
− V
Figure 11. V
CC(drop)
Level With a Square Voltage Drop to Generate a POR/Brownout Signal
Summary of Contents for MSP430CG4616IPZ