Getting Started
47
JAJU324B – March 2015 – Revised July 2017
翻訳版
—
最新の英語版資料
http://www-s.ti.com/sc/techlit/TIDU832
Copyright © 2015–2017, Texas Instruments Incorporated
EMI/EMC
規格準拠、産業用温度範囲のデュアルポート・ギガビット・イーサネットの
リファレンス・デザイン
4.2.4
Powering the TIDA-00204 Reference Design
Insert the micro SD-Card with TIDA-00204 firmware image into the TIDA-00204 micro SD-Card cage.
Connect a 24-V power supply with at least a 250-mA output current. After that, the three green LEDs (D2,
D3, and D14) will turn on. If the LEDs does not turn on, one of the jumpers J1 and J3 are not connected.
Connect the micro USB cable from the TIDA-00204 reference design to the PC. Now the XDS100 v2 PC
USB driver is installed on the PC. If PC does not find this driver, install CCS 6 to get the driver.
Invoke a terminal program, like TeraTerm that can connect to the virtual COM port. Setup the terminal
program in Serial Console Mode and set the parameters as seen in
.
表
表
19. Terminal Program Serial Console Configuration
BAUD RATE
DATA
PARITY
STOP
FLOW CONTROL
115200
8-bit
None
1-bit
None
Afterwards, press the reset button on the board. For the location of the reset button, see
.
Now on the terminal program, the boot sequence of the TIDA-00204 reference design is printed. See
for terminal program printout.
図
図
33. Virtual COM Port Connection During Boot