Getting Started
48
JAJU324B – March 2015 – Revised July 2017
翻訳版
—
最新の英語版資料
http://www-s.ti.com/sc/techlit/TIDU832
Copyright © 2015–2017, Texas Instruments Incorporated
EMI/EMC
規格準拠、産業用温度範囲のデュアルポート・ギガビット・イーサネットの
リファレンス・デザイン
4.3
Evaluating the TIDA-00204 Dual-Port Gigabit Ethernet Reference Design
With the board powered up, the next step is to connect the Ethernet link partner.
Connect a link partner to either port 1 or port 2, depending on the link partner autonegotiate will setup
10/100/1000 network capability. Now the Ethernet LEDs will light up showing link status and Ethernet
speed.
The status LEDs have the following functionality see
表
表
20. DP83867 Gigabit PHY Port 1 and Port 2 Status LED Configuration
LED #
D7 / D12
D4 / D9
D5 / D10
D6 / D11
Function
Not assigned to a
specific function on
TIDA-00204
Receive or transmit
activity
1000-Mb link
established
Link established
The status LEDs are explained from left to right when looking at the board picture.
The reference design is setup to use the IP address 192.168.1.10, that is a static IP. It does not have
DHCP function enabled.
Setup the PC Network connection for static IP in the same address range as the TIDA-00204 reference
design with subnet mask 255.255.255.0. For example: 192.168.1.30.
To test the Ethernet connection there are several options: ping, provided UDP test software and a HTTP
web server. See examples below.
All Gigabit Ethernet examples demonstrated on both port 1 and port 2.
4.3.1
Ping
With the command prompt, the windows ping function can be used for initial connection test, see
.
図
図
34. Command Prompt Ping Print