Test Results
70
JAJU324B – March 2015 – Revised July 2017
翻訳版
—
最新の英語版資料
http://www-s.ti.com/sc/techlit/TIDU832
Copyright © 2015–2017, Texas Instruments Incorporated
EMI/EMC
規格準拠、産業用温度範囲のデュアルポート・ギガビット・イーサネットの
リファレンス・デザイン
shows the complete ESD test results for contact and air discharge (AD) at voltage levels, which also
exceed the requirements per IEC61800-3. This is marked accordingly.
(1)
See
for performance descriptions.
表
表
32. IEC-61000-4-2 ESD Test Results for TIDA-00204
PHENOMENON
BASIC
STANDARD
LEVEL
TIDA-00204
CONNECTOR
UNDER TEST
PERFORMANCE
CRITERION
(1)
COMMENT
ESD
IEC61000-4-2
±4-kV CD
RJ45 port 1 and 2
B
ESD
IEC61000-4-2
±6-kV CD
RJ45 port 1 and 2
B
Not required per IEC61800-3
ESD
IEC61000-4-2
±8-kV CD
RJ45 port 1 and 2
C
Not required per IEC61800-3
ESD
IEC61000-4-2
±8-kV AD
RJ45 port 1 and 2
B
ESD
IEC61000-4-2
±15-kV AD
RJ45 port 1 and 2
B
Not required per IEC61800-3
Class B was claimed when there was a network utilization reduction, but no link loss. Only for 8-kV ESD
CD was the link lost and a power-cycle of the boards was required.
shows the network utilization
during the entire ESD test for ±6-kV CD ESD strikes. It can be seen that the network utilization is reduced
due to lost packets, but the link does not drop.
図
図
63. IEC61000-4-2 ±6-kV ESD CD: Network Utilization With UDP Packet Throughput Test on Port 1 and
Port 2 (Measured on Two Separate Laptops)