23 mm Transponder Reference Manual
25 July 1996
Page 20 of 22
11. Environmental Data and Reliability
PARAMETER
CONDITIONS
MIN.
NOM.
MAX.
UNIT
Programming cycles
Note 1
25 oC
100 k
cycles
Data retention time
Note 1
100k cycles
@ 25oC
storage
temperature
10
years
EM Radiation immunity
1...512 MHz
100
V/m
EM Radiation immunity
512..1000MHz
50
V/m
ESD Immunity
IEC 801-2
2
kV
X-ray dose
2000
RAD
Vibration (Note 2)
IEC 68-2-6, Test Fc
Shock
IEC 68-2-27, Test Ea
Note 1:
Cumulative failure rate 1%.
Note 2:
f = 10 - 2000 Hz.
12. Memory
PARAMETER
DATA
Memory size
80 bits
Memory organization
1 block
Identification data
64 bit
Error detection (Data BCC)
CRC - CCITT , 16 bit
13. Package
PARAMETER
DATA
Dimensions
23 mm x 3.85 mm ( see figure 3)
Weight
0.6g