www.ti.com
5.83 Port Error Rate Enable CSR n (SPn_RATE_EN)
SRIO Registers
Each of the four ports is supported by a register of this type (see
Table 160
). The port error rate enable
CSR n (SPn_RATE_EN) is shown in
Figure 146
and described in
Table 161
.
Table 160. SPn_RATE_EN Registers and the Associated Ports
Register
Address Offset
Associated Port
SP0_RATE_EN
2044h
Port 0
SP1_RATE_EN
2084h
Port 1
SP2_RATE_EN
20C4h
Port 2
SP3_RATE_EN
2104h
Port 3
Figure 146. Port Error Rate Enable CSR n (SPn_RATE_EN)
31
30
24
ERR_IMP_
Reserved
SPECIFIC
R/W-0
R-00h
23
22
21
20
19
18
17
16
CORRUPT_
CNTL_SYM_
RCVED_
PKT_
RCVED_PKT_
RCVED_
Reserved
CNTL_SYM_
UNEXPECTED_
PKT_NOT_
UNEXPECTED_
WITH_BAD_
PKT_OVER_
Reserved
EN
ACKID_EN
ACCPT_EN
ACKID_EN
CRC_EN
276B_EN
R-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R-0
15
8
Reserved
R-0
7
6
5
4
3
2
1
0
NON_
UNSOLICITED_
PROTOCOL_
DELINEATION_
LINK_
Reserved
OUTSTANDING_
Reserved
ACK_CNTL_
ERROR_EN
ERROR_EN
TIMEOUT_EN
ACKID_EN
SYM_EN
R-0
R/W-0
R/W-0
R-0
R/W-0
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = Value after reset
Table 161. Port Error Rate Enable CSR n (SPn_RATE_EN) Field Descriptions
Bit
Field
Value
Description
31
EN_IMP_SPECIFIC
Rate counting enable for implementation-specific errors
0
Disable error rate counting of implementation specific errors
1
Enable error rate counting of implementation specific errors.
30–23
Reserved
0
These read-only bits return 0s when read.
22
CORRUPT_CNTL_SYM_ENABLE
Rate counting enable for corrupt control symbols
0
Disable error rate counting of a corrupt control symbol.
1
Enable error rate counting of a corrupt control symbol.
21
CNTL_SYM_UNEXPECTED_ACKID_EN
Rate counting enable for control symbols with unexpected ackIDs
0
Disable error rate counting of an acknowledge control symbol with
an unexpected ackID.
1
Enable error rate counting of an acknowledge control symbol with
an unexpected ackID.
20
RCVED_PKT_NOT_ACCPT_EN
Rate counting enable for packet-not-accepted control symbols
0
Disable error rate counting of received packet-not-accepted control
symbols.
1
Enable error rate counting of received packet-not-accepted control
symbols.
SPRUE13A – September 2006