www.ti.com
5.98 Port Multicast-Event Control Symbol Request Register n (SPn_MULT_EVNT_CS)
SRIO Registers
Each of the four ports is supported by a register of this type (see
Table 186
). The port multicast-event
control symbol request register n (SPn_MULT_EVNT_CS) is shown in
Figure 161
and described in
Table 187
.
Table 186. SPn_MULT_EVNT_CS Registers and the Associated Ports
Register
Address Offset
Associated Port
SP0_MULT_EVNT_CS
1400Ch
Port 0
SP1_MULT_EVNT_CS
1410Ch
Port 1
SP2_MULT_EVNT_CS
1420Ch
Port 2
SP3_MULT_EVNT_CS
1430Ch
Port 3
Figure 161. Port Multicast-Event Control Symbol Request Register n (SPn_MULT_EVNT_CS)
31
0
MULT_EVNT_CS
W-0
LEGEND: R/W = Read/Write; R = Read only; -n = Value after reset
Table 187. Port Multicast-Event Control Symbol Request Register n (SPn_MULT_EVNT_CS) Field
Descriptions
Bit
Field
Value
Description
31–0
MULT_EVNT_CS
Write to send Control Symbol, data is ignored. Reads return 000000h.
SPRUE13A – September 2006
Serial RapidIO (SRIO)
239
Submit Documentation Feedback