4.6 Load Transient Response
shows the TPS56C20EVM-614 response to load transient. The current step is from 50 mA to 12
A (0% to 100% of rated load), with a slew rate of 500 mA/µs.
shows the total peak-to-peak output
voltage variation.
Figure 4-5. TPS56C20EVM-614 Load Transient Response
4.7 Output Voltage Ripple
shows the TPS56C20EVM-614 output voltage ripple. The output current is the rated full load of 12 A.
Figure 4-6. TPS56C20EVM-614 Output Voltage Ripple
Test Setup and Results
12
TPS56C20 Buck Converter Evaluation Module User's Guide
SBAU227A – MARCH 2014 – REVISED JUNE 2021
Copyright © 2021 Texas Instruments Incorporated