Time (5
P
s/div)
Cu
rr
en
t (A)
Voltag
e (
V)
-2
-1
0
0
2
1
4
2
6
3
8
4
10
5
12
6
D004
I VBUS
VBUS
1/RPP5V
VREV5V0
IREV5V0
I
V
36
SLVSDC2B – FEBRUARY 2016 – REVISED AUGUST 2016
Product Folder Links:
Copyright © 2016, Texas Instruments Incorporated
Figure 21. 5V Switch I-V Curve
9.3.3.3 PP_5V0 Current Sense
The current from PP_5V0 to VBUS is sensed through the switch and is available to be read digitally through the
ADC.
9.3.3.4 PP_5V0 Current Limit
The current through PP_5V0 to VBUS is limited to ILIMPP5V and is controlled automatically by the digital core.
When the current exceeds ILIMPP5V, the current-limit circuit activates. Depending on the severity of the over-
current condition, the transient response will react in one of two ways:
and
show the
approximate response time and clamping characteristics of the circuit for a hard short while
shows the
shows the approximate response time and clamping characteristics for a soft short with a load of 2
Ω
.
Figure 22. PP_5V0 Current Limit with a Hard Short