Texas Weather Instruments, Inc.
18
WR-25 Instruction Manual
10) Rain increment value ( the value that is added for each click of the rain
collector, most rain collectors should be set for 0.01 including TWI)
11) Daily rainfall history register
12) Monthly rainfall history register
13) Term rainfall history register
14) Report output interval HI, sets the automatic data dump interval to the
RS232. Value can be in hours or minutes depending on the setting of the
report interval units (19)
15) Report output interval LO, sets the automatic data dump interval to the
RS232. Value can be in minutes or seconds depending on the setting of the
report interval unites (19).
16) Report Min/Max turns on the min-max function for the log and the report
output (for the printer).
17) Report end of day- sends a formfeed at midnight to the RS-232 (for the
printer).
18) Report Interval Units sets the ouput values to minutes or seconds.
19) Sets which command the report output will use, r, R, q or Q.
20) Sets the years..
21) Sets the month.
22) Sets day of month.
23) Sets the day of the week.
(1=Sunday, 2=Monday, 3= Tuesday,
4=Wednesday, 5=Thursday, 6= Friday, 7=Sunday)
24) Sets hours in 24 hour format..
25) Sets minutes
26) Sets Seconds.
27) Sets the logging interval hours
(saves data in the units memory when set)
28) Sets the logging interval minutes.
29)
0
for English or
1
for Metric scale
30) Sets the ID number (
0 through 255)
31) Displays number of power ups
(0 through 255)
32) Displays the rainfall rate interval in minutes.
33) Wind Speed scale, changes wind speed to knots when set to 1. A 0
setting when in English will output miles per hour and a 0 when in metric will
output kilometers per hour.
34) Time display, when set to 0 the unit will display time in a 24 hour military
format. When set to 1 the unit will be in AM or PM.
35) Aux disable, when set to 0 will cycle the temperature display through three
values, indoor temp, outdoor temp and the aux value (aux temperature or solar).
When Aux disable is set to 1 the temperature display will cycle through indoor
and outdoor temperatures only.
36) Wind speed and direction, when set to 0 the unit outputs one minute
average wind data to the RS-232 port. When set to 1 the output is instant. This
setting does not effect the display which has its own button.
37) Selects baud rate, 0=38.4 1=19.2, 2=9600, 3=4800, 4=2400, 5=1200,
6=600, 7=300.
(Warning! Do not change this number unless you