background image

Premier Elite Com GSM Module Installation Manual 

INS315-4 

2.

 

Panel Configuration 

Premier & Premier Elite 24/48/88/168/640 

Text Messaging and Upload Download via GSM 

GSM Mode (panel port programmed as GSM Module, Dynamic IP SIM card) 

1.

 

Enter “Engineers Programming” mode and select “UDL/Digi Options”, then select “Com Port Setup”. 
Ensure Com Port is programmed as “GSM Module”. 

Now select the “Digi Options” menu and make sure that “Digi Option 1” is programmed for “Digi is Enabled”. 

Now select “Program Digi” and ensure the following options are programmed for one of the ARC options: 

a)

 

Protocol: “SMS Messaging”. 

b)

 

Primary No: The number of the recipient’s mobile telephone. 

c)

 

Secondary No: Secondary mobile telephone number (if required). 

d)

 

Account No: Leave blank. 

e)

 

Dialling Attempts: Program as required. 

f)

 

Report Areas: Program as required. 

g)

 

Reports: Program as required. 

h)

 

Config.: Program as required. 

i)

 

Protocol Options : Program as required. 

j)

 

UDL Options : Change rings before answer to 1 if using GSM Upload/Download. 

All three status LED’s should now be on,(it can take up to 1 minute for the LED's to become stable.) if status LED 
3 is off or flashing, this indicates a low GSM signal level.  If the signal level is low, try moving the antenna to 
improve the reception.  

Using the SMS Control Commands 

Control commands can be sent to the 

Premier Elite ComGSM

 module to allow remote control and interrogation 

of the alarm system. 

1.

 

Select the send text message option on your mobile telephone. 

2.

 

Enter the telephone number of the 

Premier Elite ComGSM

 module. 

3.

 

Enter the text command, see SMS Control Commands. 

4.

 

Select send on your mobile telephone. 

When using the SMS Control Commands shown in the tables below the following should be noted: 

???? = User code, this must proceed all commands. 

[areas] = Areas 1 to 8 or A to P. If the areas are not specified then all areas will be selected. 

[s] = Send back status report 

(zones) = List of zones, each zone must separated by a space e.g. 1 12 167 etc. 

(outputs) = List of outputs, e.g. 1234 etc. 

(message) = A maximum of 32 characters. 

 

Summary of Contents for Premier Elite ComGSM

Page 1: ...Premier Elite ComGSM Installation Manual INS315 4...

Page 2: ...eport system events alarms arm disarm etc via text messaging to mobile telephones Remotely arm disarm and obtain current status of the alarm system via text messaging Upload Download Via GSM Alarm rep...

Page 3: ...please check with your service provider SIM cards purchase Texecom DO NOT supply SIM cards These will need to be sourced locally and care should be taken to source SIM cards in the country where the...

Page 4: ...ComGSM Remove the screw cover by locating the two small indents on the upper and lower edge with a small screwdriver Excessive force is not required Remove the retaining screw If removal from mountin...

Page 5: ...to power the Premier Elite ComGSM when using APNProgrammer 5 Status LED s see table below 6 Tamper Switch connector 7 Power LED Green 8 Tamper switch not used in this housing 9 Option switches see tab...

Page 6: ...s water tanks and electronic equipment e g photocopiers fax machines etc These can have similar effects to metal roofs Reliable operation is unlikely with a low signal strength If the display shows th...

Page 7: ...the antenna as high as possible 5 Unlock the SIM socket by sliding the locking tab downwards Insert the SIM card into the holder with the chamfered corner to the top left Push the holder back into pos...

Page 8: ...equired j UDL Options Change rings before answer to 1 if using GSM Upload Download All three status LED s should now be on it can take up to 1 minute for the LED s to become stable if status LED 3 is...

Page 9: ...3 s 5678 parm 1 part arm 1 all areas no status Disarm System darm areas s 5678 darm abcs disarm areas abc and report back status Reset System reset areas 5678 reset reset all areas Omit Zone s omit zo...

Page 10: ...ol Program as required b Account No Program as required c Dialling Attempts Program as required d Report Areas Program as required e Reports Program as required f Config Program as required g Protocol...

Page 11: ...h the essential requirements and other relevant provisions of Directive 2004 108 EC Weee Directive 2002 96 EC WEEE directive Products marked with this symbol cannot be disposed of as unsorted municipa...

Page 12: ...Texecom Limited Bradwood Court St Crispin Way Haslingden Lancashire BB4 4PW England Technical Support UK Customers 08456 300 600 International Customers 441706 233875 Texecom Ltd 2012 INS315 4...