background image

No. 

Items 

Range 

Default 

Description 

P15 

Mending stitch mode 

0-4 

0: half stitch 

1: one stitch 

2: continuous half stitch 

3: continuous one stitch 

4: Back-tacking when machine stop or pause 

P21 

The position of the pedal for 
accelerating 

30-1000 

520 

 

P22 

The position of the pedal for the 
stop 

30-1000 

420 

 

P24 

The position of the pedal for 

thread trimming 

30-1000 

130 

 

P27-N6 

Auto count selection 

0-50 

0: P41 item trimming counter not count automatically. 
1-50: Counter trimming times 

P27-N12 

Boot display counter interface 
selection 

0-1 

0: OFF 
1: ON 

P27-N13 

Thread trimming counter mode 
selection 

0-1 

0: Additive sewing counter   
1: Subtractive sewing counter 

P29 

The

 

strength of thread trimming 

stop 

1-45 

32 

 

P38 

Automatic thread trimming 
function selection 

ON/OFF 

ON 

 

P41 

Counter display 

0-9999 

Display the quantity of finished sewing piece.

 

Long-press “-” 

key to clear the count 

P42-N01 

The control system version 
number 

 

 

 

P42-N02 

The panel version number 

 

 

 

P42-N03 

Speed 

 

 

 

P42-N04 

The pedal AD 

 

 

 

P42-N05 

The mechanical angle(up 
position) 

 

 

 

P42-N06 

The mechanical angle(down 
position) 

 

 

 

P42-N07 

Busbar voltage AD 

 

 

 

P43 

Direction of motor rotation 

CCW/CW 

CCW 

CW: Clockwise 
CCW: Counterclockwise 

P44 

Brake strength during stopover 

1-45 

30 

 

P46 

Motor stop with a reverse angle 
after trimming function 

ON/OFF 

OFF 

 

P47 

Adjust the reverse angle when 
motor stop after trimming 

50-200 

160 

After thread trimming, start from the upper needle position and 
adjust the angle of the needle lift in reverse operation. 

P48 

The minimum speed 
(positioning speed) (rpm) 

100-500 

210 

Adjust the minimum speed 

P49 

Thread trimming speed (rpm) 

100-500 

300 

Adjust the motor speed during the thread trimming cycle 

P54 

Thread trimming action time 
(ms) 

10-990 

200 

 

P56 

Power on and positioning 

0-2 

0: Always not to find the up needle position 

1: Always to find the up needle position 

2: If the motor is not into the up needle position, it will find the 