No.
Items
Range
Default
Description
up needle position
P58
Up needle position adjustment
0-2399
1950
Up position adjustment, the needle will advance stop when the
value decreased, the needle will delay stop when the value
increased.
P59
Down needle position
adjustment
0-2399
750
Down position adjustment, the needle will advance stop when
the value decreased, the needle will delay stop when the value
increased.
P60
Testing speed (rpm )
100-3700
3500
Setting testing speed.
P61
Testing A
ON/OFF
OFF
Continuous running testing.
P62
Testing B
ON/OFF
OFF
Start and stop testing with all functions.
P63
Testing C
ON/OFF
OFF
Start and stop testing without all function.
P64
Test run time
1-250
30
P65
Test stop time
1-250
10
P66
Machine protection switch
selection
0-1
1
0
:
Disable
1
:
Testing zero signal
P70
Type
1-45
P72
Up needle position adjustment
0-2399
Adjust up needle position, the displayed value will change with
the position of the handwheel, press "S" key to save the current
position (value) as up needle position.
P73
Down needle position
adjustment
0-2399
Adjust down needle position, the displayed value will change
with the position of the handwheel, press "S" key to save the
current position (value) as down needle position.
P80
Trimming engage angle
5-359
18
P82
Trimming retract angle
5-359
172
P83
Stopping strength after trimming
10-100
20
P86
Up and down needle position
distance
100-1400
1200
Up and down positioning distance angle (1 degree for every 4
values)
P88
Stopover distance
10-100
40
P89
AC overvoltage setting
500-1023
880
P92
Correct the electrical angle of
motor
160
Reading the initial Angle of encoder, the factory default was
set, please do not change the values (parameter value cannot be
changed manually, random change it will result the control box
and motor abnormal or damaged).
P110
Trimming back time (ms)
60-990
60
Make sure the thread trimming device returns to its original
position
P119
Solenoid overcurrent protection
alarm selection
0-1
1
0: no alarm, turn off the output
1: alarm, and stop
Note: the initial value of parameters is for reference only, and the actual value of parameters is subject to the real object.