background image

No. 

Items 

Range 

Default 

Description 

up needle position 

P58 

Up needle position adjustment 

0-2399 

1950 

Up position adjustment, the needle will advance stop when the 

value decreased, the needle will delay stop when the value 

increased. 

P59 

Down needle position 
adjustment 

0-2399 

750 

Down position adjustment, the needle will advance stop when 

the value decreased, the needle will delay stop when the value 

increased. 

P60 

Testing speed (rpm ) 

100-3700 

3500 

Setting testing speed. 

P61 

Testing A 

ON/OFF 

OFF 

Continuous running testing. 

P62 

Testing B   

ON/OFF 

OFF 

Start and stop testing with all functions. 

P63 

Testing C 

ON/OFF 

OFF 

Start and stop testing without all function. 

P64 

Test run time 

1-250 

30 

 

P65 

Test stop time 

1-250 

10 

 

P66 

Machine protection switch 
selection 

0-1 

0

Disable 

1

Testing zero signal 

P70 

Type 

1-45 

 

 

P72 

Up needle position adjustment 

0-2399 

 

Adjust up needle position, the displayed value will change with 

the position of the handwheel, press "S" key to save the current 

position (value) as up needle position. 

P73 

Down needle position 
adjustment 

0-2399 

 

Adjust down needle position, the displayed value will change 

with the position of the handwheel, press "S" key to save the 

current position (value) as down needle position. 

P80 

Trimming engage angle 

5-359 

18 

 

P82 

Trimming retract angle 

5-359 

172 

 

P83 

Stopping strength after trimming 

10-100 

20 

 

P86 

Up and down needle position 

distance 

100-1400 

1200 

Up and down positioning distance angle (1 degree for every 4 

values) 

P88 

Stopover distance 

10-100 

40 

 

P89 

AC overvoltage setting 

500-1023 

880 

 

P92 

Correct the electrical angle of 

motor 

 

160 

Reading the initial Angle of encoder, the factory default was 

set, please do not change the values (parameter value cannot be 

changed manually, random change it will result the control box 

and motor abnormal or damaged). 

P110 

Trimming back time (ms) 

60-990 

60 

Make sure the thread trimming device returns to its original 

position 

P119 

Solenoid overcurrent protection 

alarm selection 

0-1 

0: no alarm, turn off the output 

1: alarm, and stop 

Note: the initial value of parameters is for reference only, and the actual value of parameters is subject to the real object. 

 

 

 

 

 