background image

3 Error Code List 

 
4 Port Diagram 

6P Function Port Description 

 

 

1. Thread trimming electromagnet: 1, 4 (+32V) 

2. Mending stitch key: 2(signal), 5 (DGND) 

3. LED Light: 3 (+5V), 6 (DGND) 

   

Error Code 

Problem 

Measure 

E01 

Over-voltage 

Turn off the system power and check whether the power supply voltage 

is correct. (Or whether it exceeds the specified rated voltage). 

E02 

Low-voltage 

Turn off the system power and check whether the power supply voltage 

is correct. (

Or

 whether it is lower than the specified rated voltage). 

E03 

Abnormal communication 
between the main CPU and 
the driver CPU 

Turn off the power and check whether the connector is connected to the 

operation panel and the cable condition. 

E05 

Speed control unit 
connection is abnormal 

Please turn off the power and check whether the connector is connected 

to the speed controller and the cable condition. 

E07 

Main shaft motor rotating 

abnormally 

Please rotate handwheel to check if the spindle motor is locked. Check 

if the encoder cable of the motor and the power cable of the motor are 

connected to the connector. Check if the power supply voltage is 

normal and whether the sewing speed is too high. 

E10 

Solenoid over-current 
protection 

Turn off the system power supply, please check the solenoid (solenoid 
valve) connector or solenoid (solenoid valve) is broken or not. 

E09 
E11 

Positioning signal error 

Turn off the machine, please check if the encoder in bad connection or 
is too loose. To get it right and turn on. If there are still errors, please 
replace the control box and call for customer service. 

E14 

Encoder signal error. 

Turn off the system power supply, please check motor encoder 
connector if loose or fall off, renew to normal then restart system. 

E15 

Main shaft motor 
overcurrent error 

Turn off the power, and then turn it on again. 

E17 

Head fall error 

Please raise machine head and turn on the power again. Check if the 
head down switch is damaged. 

E20 

Main shaft motor rotating 

abnormally at startup 

Turn off the power and check whether the encoder cable of the motor 
and the power cable of the motor are connected to the connector. 