15
2-7. ARB
2-7-1. ARB
–Add Built-In Waveform
Example: ARB Mode, Exponential Rise. Start 0, Length 100, Scale 327.
Output:
50
Ω
CH1
1.
Press ARB, Built in (F3),
Wave (F4), Math(F2),
use the scroll wheel to
select Exporise and
then press Select(F5).
ARB
Built in
Wave
Math
Select
2.
Press Start (F1), 0 +
Enter (F2), Return.
Start
0
Enter
Return
3.
Press Length (F2), 100,
Enter (F2), Return.
Length
1
0
0
Enter
Return
4.
Press Scale (F3), 327,
Enter (F2), Return,
Done (F5).
Scale
3
2
7
Enter
Return
Done
2-7-2. ARB- Add Point
Example: ARB Mode, Add point, Address 40, data 300.
Output:
50
Ω
CH1
1.
Press ARB, Edit (F2),
Point (F1), Address (F1)
ARB
Edit
Point
Adress
2.
Press 4 + 0 + Enter (F2),
Return
4
0
Enter
Return
3.
Press Data (F2), 3+0+0,
Enter (F2).
Data
3
0
0
Enter
2-7-3. ARB- Add Line
Example: ARB Mode, Add line, Address:Data (10:30, 50:100)
Output:
50
Ω
CH1
1.
Press ARB, Edit (F2),
Line (F2), Start ADD
(F1).
ARB
Edit
Line
Start ADD
2.
Press 1 + 0 + Enter (F2),
Return.
1
0
Enter
Return
Summary of Contents for FGX-2220