7-5. Operating Mode Description
7-5-1. CC Mode
CC Mode
When the unit is set to CC mode it will operate
as a constant current load when connected to a
constant voltage source. This means the unit will
sink a designated amount of current, up to the
rated power level, regardless of the voltage. This
is illustrated below.
CC Mode
Load Input
Voltage
Load Current
CC Current
Value
CC+CV Mode
When CC+CV mode is enabled, the unit will act
as constant current load after the input voltage is
greater than the user-defined CV level. At the
CV level, the unit works as a constant voltage
load. This mode effectively creates a voltage
ceiling before the unit operates in CC mode. The
diagram below illustrates this.
CC + CV Mode
Load Input
Voltage
Load Current
CV level
CC Current
Value
Note that when the source voltage is less than
the CV level, no current will flow due to a very
high impedance.