58
2-8-2. File Types
Memory Data
Memory data contains general settings and is
used for creating programs. Memory Data
contains the operating mode, range, response
and Go/NoGo settings. Memory data can be
stored both internally and externally to USB.
Preset data and Memory data store the same
contents.
Internal Format M001 ~ M256
External Format model no_file no.M
example: 3021_01.M
Setup Data
Setup data contains all general configuration
settings, protection settings, program and
program chain settings, as well as parallel
configuration settings.
Internal Format 1 ~ 100
External Format model no_file no.S
example: 3021_00.S
Preset Data
Preset Data contains the same settings as the
Memory Data. Preset Data contains the
operating mode, range, response and Go-NoGo
settings.
Internal Format P0 ~ P9
External Format model no_file no.P
example: 3021_00.P
NSeq Data
NSeq Data contains the Normal Sequence
settings.
Internal Format None
External Format model no_file no.N
example: 3021_00.N
FSeq Data
FSeq Data contains the Fast Sequence settings.
Internal Format None
External Format model no_file no.F
example: 3021_00.F
2-8-3. Saving Files to Internal Memory
Description
When saving Memory, Setup or Preset Data to
internal memory, the currently active setting is
saved to one of the internal memory slots.
Memory Data has 256 memory slots, Setup Data
has 100 memory slots and Preset Data has 10
memory slots.
Summary of Contents for LSG SERIES
Page 8: ......
Page 23: ...11 GRA 414 E EIA standard 132 382 5 477 6 GRA 414 J JIS standard 149 382 5 477 6 ...
Page 149: ...137 7 6 Operating Area LSG 175 ...
Page 150: ...138 LSG 350 ...
Page 151: ...139 LSG 1050 ...
Page 166: ......