Note
The +CV settings apply to all the applicable
operating modes.
For example: The +CV settings made in CR
mode will be carried over to the +CV settings in
CC and CP mode.
Note
+CV settings cannot be controlled with external
control.
2-1-7. Turning on the Load
Description
1.
The load can be turned on and off by pressing the
Load
On/
Off
key.
The
Load
On/
Off
key will turn orange when the load
is “on”.
The LOAD icon in the Main Frame status panel
will turn orange when the load is on.
Note
The load can be set to automatically turn on at
start up. See page 45.
The load can be turned on via remote control.
See the programming manual.
The load can be turned on via external control.
See page 109.
Display
Mode
CP
IRange
H 35A
VRange
L 15V
Function
Dynamic
Configure
1.500
V
0.000
A
1.50
w
Timer1
0.025
Level2
0.00
Level1
0.00
LOAD
RS232
Fine
31/Oct/2013
mS
W
W
LOAD on
2-1-8. Shorting the Load
Description
The Short key can be used to simulate a short
circuit of the load input terminals. A short circuit
is simulated by:
Setting the current to the maximum value in CC
mode.
Setting the resistance to the minimum value in
CR mode.
Setting the voltage to the minimum value in CV
mode.
Setting the power to the maximum value in CP
mode.
When the load is shorted, the external
controller also sends a short signal. See page
112 for usage details.