72
9-7-30. Sending addresses of all connected slave units (IF-41GU/IF-41USB only)
・
Response to the SLV? Command
SLV
*
,
*
,
*
,
・・・
The system address of all slave units connected are displayed in order.
Only SLV is sent when no units are connected. System address 1 is
not returned since it is the address of the local bus master.
9-7-31. Sending optional board ID (IF-41GU/IF-41USB only)
9-7-32. Information of constant-voltage/constant-current mode
CC1,
**
,
****
・
Command is sent from slave unit to master unit when the service request function is enabled by
the SR1 command and the constant-voltage (CV) mode changes into the constant-current (CC)
mode or the constant-current mode changes into the constant-voltage mode.
※
Always 0 if no channels exist.
9-7-33. Information of alarm status
UU1,
**
,
****
・
Command is sent from slave unit to master unit when the service request function is enabled by
the SR1 command and an OHA or external alarm signal brings the PW-A power supply unit into
the alarm status or the PW-A power supply unit recovers from the alarm status.
9-7-34. Information about completion of storing the set data
MW1
、**
・
The slave unit sends this command to the master unit when storage of the set data in the
EEPROM caused by the MW1 command is complete.