background image

CL-B101D40-TCRTD Manual (d0099)

Page 9

STEP M

STEP N

STEP O

STEP P

STEP Q

STEP R

STEP S

STEP T

STEP U

[orAn]

[rEd]

NOTE: Will only 

appear if a tricolor 

display is installed

[orAn]

[rEd]

[orAn]

[rEd]

[orAn]

[rEd]

[orAn]

[rEd]

BARGRAPH COLOR 

PROGRAMMING MODE

Operational Display

Operational Display

From From Step L of

Setpoint Setting and Relay

Configuration Page 8

L or h

L or h

L or h

L or h

To comply with the latest safety requirements, the tri-color bargraph is designed like a traffic light, to 

display either red, orange or green, but only one color at a time.  When the bar reaches a selected 

color change point, the entire bar will change to the color designated for that zone.  This eliminates any 

ambiguity as to the signal status, especially just after transitioning to a new zone.

First (Step Q) is to select the color to be displayed, when the bar is “below*”, whichever set point is set 

to the lowest position.

Second (Steps R, S, T, and U) is to select the color to be displayed when the bar is above each specific 

set point, regardless of the order or position to which the set points are set.

However, if two or more setpoints with differently specified colors are positioned at the same set point 

value, the color specified for the set point with the highest identifying number will be displayed. When 

set points are set to the same value, the SP4 color overrides the SP3 color, the SP3 color overrides the 

SP2 color, and the SP2 color overrides the SP1 color.

STEP Q  Select Bargraph Color when the bar is BELOW* the Setpoint that is set to the lowest 

position

 

1)  Using the   and   buttons, select the desired bargraph color [grn], [oran] or [red]

 

2)  Press the 

P

 button. Display toggles between [CSP1] and the previous color setting.

STEP R  Select Bargraph Color when the bar is ABOVE* SP1 Setpoint

 

1)  Using the   and   buttons, select the desired bargraph color [grn], [oran] or [red]

 

2)  Press the 

P

 button. Display toggles between [CSP2] and the previous color setting.

STEP S  Select Bargraph Color when the bar is ABOVE* SP2 Setpoint

 

1)  Using the   and   buttons, select the desired bargraph color [grn], [oran] or [red]

 

2)  Press the 

P

 button. Display toggles between [CSP3] and the previous color setting.

STEP T  Select Bargraph Color when the bar is ABOVE* SP3 Setpoint

 

1)  Using the   and   buttons, select the desired bargraph color [grn], [oran] or [red]

 

2)  Press the 

P

 button. Display toggles between [CSP4] and the previous color setting.

STEP U  Select Bargraph Color when the bar is ABOVE* SP4 Setpoint

 

1)  Using the   and   buttons, select the desired bargraph color [grn], [oran] or [red]

 

2)  Press the 

P

 button. The meter exits the setpoint mode and returns to the operational 

display.

The Bargraph Color programming mode is now complete.

STEP M  Set Relay Activation mode [rLYS] for SP1

 

(h) High the relay energizes when the setpoint is exceeded. (L) Low the relay energizes below 

the setpoint. The setpoint is indicated from left to right SP1, SP2, SP3, SP4.

 

1)  Using the   and   buttons, select (L) or (h) for the first digit, which corresponds to SP1.

 

2)  Press the 

P

 button.  The SP2 Relay Activation digit begins to flash, and its decimal point is lit.

STEP N  Set High (h) or Low (L) for SP2

 

1)  Using the   and   buttons, select (L) or (h) for the second digit, which corresponds to SP2.

 

2)  Press the 

P

 button.  The SP3 Relay Activation digit begins to flash, and its decimal point is lit.

STEP O  Set High (h) or Low (L) for SP3

 

1)  Using the   and   buttons, select (L) or (h) for the third digit, which corresponds to SP3.

 2) 

Press the 

P

 button.  The SP4 Relay Activation digit begins to flash, and its decimal point is lit.

STEP P  Set High (h) or Low (L) for SP4

 1) 

Using the   and   buttons, select (L) or (h) for the fourth digit, which corresponds to SP4. 

2)  Press the 

P

 button. 

 

If a mono-color red or green display is installed then the Setpoint Relay Programming Mode is now complete and the 

meter returns to the operational display. 

If a tricolor bargraph display is installed then the Bargraph Color Programming Mode will be entered and 

display toggles between [CoL] and the previous setting. Color selection menu will be displayed. 

Setpoint Setting and Relay Configuration Mode Continued

Bargraph Color Programming Mode

Summary of Contents for CL-B101D40-RTD

Page 1: ...or below Lo each setpoint Digital display blanking Decimal point setting Four level brightness control LEOPARD FAMILY Input Specs Depends on Input signal conditioner A D Converter 14 bit single slope...

Page 2: ...direction indicated by the arrow When an alternative dotted line is shown this indicates that an alternative logic branch will be followed when a particular option is present When two buttons are sho...

Page 3: ...999 seconds Pump PUM Hysteresis hYSt Hysteresis hYSt Hysteresis hYSt Setpoint 3 SP3 Setpoint 4 SP4 Operational Display MAIN MENU BRIGHTNESS AND SETPOINT VIEW MODE Bargraph Center Point Display Selecti...

Page 4: ...E STEP A Calibration Mode STEP B Calibration Mode To Digital Span Selection for Bargraph Display Page 5 cAL out iP branch will only appear if the analog output option is installed otherwise cAL on goe...

Page 5: ...between Cto and oFF the software is detecting that the optional analog output hardware is NOT installed Digital Span Selection For Bargraph Display Bargraph does not light up for Input Signals up to...

Page 6: ...igh and AnLo analog low can be reversed to provide a 20 to 4mA output The digital span selected can be as small as two counts when using the analog output to function as a Control or Alarm Driver Smal...

Page 7: ...nd 18 see Rear Panel Pinouts on page 10 Using the and buttons adjust the analog output to the desired low value as measured on the multimeter cLo may be adjusted to any value from 0 3 mA to 18 mA mA o...

Page 8: ...Press the P button Display toggles between PUM and on or oFF STEP F Select Pump PUM on or oFF 1 Using the and buttons select the Pump to be ON or OFF When PUM is selected ON and SP2 is set at a value...

Page 9: ...Bargraph Color when the bar is ABOVE SP2 Setpoint 1 Using the and buttons select the desired bargraph color grn oran or red 2 Press the P button Display toggles between CSP3 and the previous color se...

Page 10: ...An analog output module is also shown as installed The CL B101D40 TCRTD uses plug in type screw terminal con nectors for all input and output connections The power supply connections pins 14 and 15 h...

Page 11: ...A 5A 5A 5A 5A 5A 5A SP4 SP3 SP2 SP1 SP1 SP2 SP3 SP4 Relay Modules with 4 Isolated 5A Form A Relays Output Carrier Board Output Carrier Board Relay Module Relay Module Input Signal Conditioner Analog O...

Page 12: ...the back panel back into the case Apply power to the meter 4 Enter the program mode and select the type of thermocouple J K R T the resolution 0 1 or 1 and the display units C or F See Page 4 of the d...

Page 13: ...10 72VDC Input Modules Partial List See www texmate com IT10 Thermocouple J K R T Selectable C F 1 0 1 IT11 RTD 100 Pt Selectable 3 4 wire C F 1 0 1 385 392 IT15 RTD 1000 Pt Selectable 3 4 wire C F 1...