CL-B101D40-TCRTD Manual (d0099)

Page 1

CL-B101D40-TCRTD 

Smart 101 segment 4 digit LED Tricolor or Mono-color 

digital bargraph controller with four fully programmable 

set points for J, K, R, and T type thermocouples and 

RTD inputs in a switchboard style case.

0.56” LEDs 

•  External transmitters or signal conditioners can be eliminated  by 

direct connection of the sensor output to Plug-in Input Signal 

Conditioners- available are thermocouples (J, K, R and T types) 

or RTD (Pt-100. 385 and 392 curves.  3 wire/4wire).  Digitally 

Linearized.

•  Optional isolated 16 bit analog output. User or factory scalable to 4 

to 20 mA, 0 to 20 mA or 0 to 10 V across any desired digital span 

from ± one count to the full scale range of – 1999 to 9999 (12000 

counts).

•  A Programmable Tricolor (Red-Green-Orange) or mono color (red or 

green), 101 segment high brightness bargraph. 

•  Red 4-digit LED display with a range of -1999 to 9999 

(12000 counts). Optional green digital display.

•  Front panel LED annunciators provide indication of setpoint status.
•  Two 9 Amp Form C, and two 4 Amp Form A or 4 x 4 Amp Form A 

relays available.

•  Auto-sensing AC/DC power supply. For voltages between  

85-265 V AC / 95-300 V DC (PS1) or 18-48 V AC / 10-72 V DC 

(PS2).

•  Provision to connect an external programming lockout switch. 
•  Provision for external DIM switch to reduce the brightest 

display setting by 50%.

•  Automatic intelligent averaging, smooths noisy signals while  

providing a fast display response to real level changes.

General Features

Specifications

•  The bargraph can display, full 

scale, any desired portion of 

the digital reading.

•  Setpoint 1 has delay-on-make 

and delay-on-break plus 

a special “pump on pump 

off” mode that creates a 

Hysteresis Band between SP1 

and SP2.

Software Features

•  Four programmable setpoints 

with adjustable Hysteresis.• 

Bargraph center zero function.

•  Relay activation can be select-

ed to occur above (hi) or below 

(Lo) each setpoint.

•  Digital display blanking.

•  Decimal point setting.

•  Four-level brightness control

LEOPARD  

FAMILY

Input Specs

: ������������������Depends on Input signal conditioner 

A/D Converter

: ��������������14 bit single slope

Accuracy

: ����������������������±(0�05% of r 2 counts)

Temp. Coeff

�: �����������������100 ppm/°C (Typical)

Warm up time

: ���������������2 minutes

Conversion Rate

: ����������10 conversions per second (Typical)

Digital Display

: ��������������

4 digit 0.56" LED red (std)

, green (optn) 

Range –1999 to 9999 counts� 

Bargraph Display

: ���������

101 segment 235º circular red (standard)

Green (optional) or tricolor (optional) LED�

Polarity

: �������������������������Assumed positive� Displays – negative

Decimal Selection

: ��������

Front panel button selectable, X•X•X•X• 

Positive Overrange

: ������Bargraph and top segments of digital display 

flash�

Negative Overrange

: ����First segment of bargraph and bottom seg-

ments of digital display flash�

Relay Output

: ����������������Two 9 Amp Form C relays, two 4 Amp Form 

A relays or 

4 x 4 Amp Form A relays

Analog Output

: �������������Isolated 16 bit user scalable mA or V

  OIC (mA out) ��������������

4-20 mA @ 0 to 500Ω max loop resistance

  OIV (volts out) ��������������

0-10 V DC @ 500 Ω or higher resistance

Power Supply

: ���������������AC/DC Auto sensing wide range supply

 

PS1 (std)

 ��������������������

85-265 VAC / 95-300 VDC, 50-400Hz 4.2W

 PS2 �����������������������������18-48 VAC / 10-72 VDC, 50-400Hz 4�2W

Operating Temp

�: ����������0 to 60°C

Storage Temp

: ���������������–20°C to 70°C

Relative Humidity

: ��������95% (non condensing)

Case Dimensions

: ��������

Bezel (4.48"x4.48") 113.8x113.8mm

 

Depth behind bezel (4.23") 107.46 mm

 

Plus (0�48”) 12�24 mm for connectors

Weight

: ���������������������������16 oz�, 1lb 4 oz when packed

Table of Contents

Bargraph Center Point Display Mode Selection  . . . 6

Bargraph Color Programming Mode  . . . . . . . . 9

Case Dimensions . . . . . . . . . . . . . . . . . . . . . . 11

Component Layout. . . . . . . . . . . . . . . . . . . . . 11

Connector Pinouts . . . . . . . . . . . . . . . . . . .10-11

Controls and Indicators  . . . . . . . . . . . . . . . . . . 2

Decimal Point and Brightness Selection  . . . . . 5

Programming Conventions. . . . . . . . . . . . . . . . 2

Setpoint Setting & Relay Conf. Mode  . . . . . .8-9

Software Features  . . . . . . . . . . . . . . . . . . . . . . 1

Software Logic Tree . . . . . . . . . . . . . . . . . . . . . 3

Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . 1

Two Point Analog Range Setting & Calibration . . . . 7

Thermocouple and RTD Type Selection Mode. . . . . .4

Digital Span Selection for Bargraph Display  . . 5

Digital Span Selection for Analog Range Output. . . 6

Functional Diagram  . . . . . . . . . . . . . . . . . . . . 10

General Features  . . . . . . . . . . . . . . . . . . . . . . . 1

Input Module Calibration Procedures  . . . . . . 12

Ordering Information  . . . . . . . . . . . . . . . . . . . 13

Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . 10

Summary of Contents for CL-B101D40-TCRTD

Page 1: ...or below Lo each setpoint Digital display blanking Decimal point setting Four level brightness control LEOPARD FAMILY Input Specs Depends on Input signal conditioner A D Converter 14 bit single slope...

Page 2: ...direction indicated by the arrow When an alternative dotted line is shown this indicates that an alternative logic branch will be followed when a particular option is present When two buttons are sho...

Page 3: ...999 seconds Pump PUM Hysteresis hYSt Hysteresis hYSt Hysteresis hYSt Setpoint 3 SP3 Setpoint 4 SP4 Operational Display MAIN MENU BRIGHTNESS AND SETPOINT VIEW MODE Bargraph Center Point Display Selecti...

Page 4: ...E STEP A Calibration Mode STEP B Calibration Mode To Digital Span Selection for Bargraph Display Page 5 cAL out iP branch will only appear if the analog output option is installed otherwise cAL on goe...

Page 5: ...between Cto and oFF the software is detecting that the optional analog output hardware is NOT installed Digital Span Selection For Bargraph Display Bargraph does not light up for Input Signals up to...

Page 6: ...igh and AnLo analog low can be reversed to provide a 20 to 4mA output The digital span selected can be as small as two counts when using the analog output to function as a Control or Alarm Driver Smal...

Page 7: ...nd 18 see Rear Panel Pinouts on page 10 Using the and buttons adjust the analog output to the desired low value as measured on the multimeter cLo may be adjusted to any value from 0 3 mA to 18 mA mA o...

Page 8: ...Press the P button Display toggles between PUM and on or oFF STEP F Select Pump PUM on or oFF 1 Using the and buttons select the Pump to be ON or OFF When PUM is selected ON and SP2 is set at a value...

Page 9: ...Bargraph Color when the bar is ABOVE SP2 Setpoint 1 Using the and buttons select the desired bargraph color grn oran or red 2 Press the P button Display toggles between CSP3 and the previous color se...

Page 10: ...p Form A relays An analog output module is also shown as installed The CL B101D40 TCRTD uses plug in type screw terminal con nectors for all input and output connections The power supply connections p...

Page 11: ...5A SP4 SP3 SP2 SP1 SP1 SP2 SP3 SP4 Relay Modules with 4 Isolated 5A Form A Relays Output Carrier Board Output Carrier Board Relay Module Relay Module Input Signal Conditioner Analog Output Module Mai...

Page 12: ...the back panel back into the case Apply power to the meter 4 Enter the program mode and select the type of thermocouple J K R T the resolution 0 1 or 1 and the display units C or F See Page 4 of the d...

Page 13: ...10 72VDC Input Modules Partial List See www texmate com IT10 Thermocouple J K R T Selectable C F 1 0 1 IT11 RTD 100 Pt Selectable 3 4 wire C F 1 0 1 385 392 IT15 RTD 1000 Pt Selectable 3 4 wire C F 1...