CL-B101D40HZ Manual (d0098)

Page 1

CL-B101D40HZ 

Smart 101 segment, 4 digit LED Tricolor or  

Mono-color digital line frequency bargraph controller 

with four fully programmable set points 

in a switchboard style case for 

monitoring, measurement, and control applications.

0.56” LEDs 

•  Frequency input. Easily user scaled.

  Optional isolated 16 bit analog output. User or factory scalable to 4 

to 20 mA, 0 to 20 mA or 0 to 10 V across any desired digital span 

from ± one count to the full scale range of – 1999 to 9999 (12000 

counts).

  A Programmable Tricolor (Red-Green-Orange) or mono color (red or 

green), 101 segment high brightness bargraph. 

  Red 4-digit LED display with a range of 99.99 to 999.9Hz 

Optional green digital display.

 

Front panel LED annunciators provide indication of setpoint status.

 

Two 9 Amp Form C, and two 4 Amp Form A or 4 x 4 Amp Form A 

relays available

.

•  Auto-sensing AC/DC power supply. For voltages between 

 

85-265 V AC / 95-300 V DC (PS1) or 18-48 V AC / 10-72 V DC 

(PS2).

•  Provision to connect an external programming lockout switch. 
•  Provision for external DIM switch to reduce the brightest

 

display setting by 50%.

•  Automatic intelligent averaging, smooths noisy signals while 

 

providing a fast display response to real level changes.

General Features

Specifications

•  The bargraph can display, full 

scale, any desired portion of 

the digital reading.

•  Setpoint 1 has delay-on-make 

and delay-on-break plus a spe

-

cial “pump on pump off” mode 

that creates a Hysteresis Band 

between SP1 and SP2.

•  Four programmable setpoints 

with adjustable Hysteresis.• 

Software Features

Bargraph center zero function.

•  Relay activation can be selected 

to occur above (hi) or below (Lo) 

each setpoint.

•  Digital display blanking.
•  Decimal point setting.
•  Four-level brightness control

Bargraph Center Point Display Mode Selection

  . . . 6

Bargraph Color Programming Mode

  . . . . . . . . 9

Case Dimensions

. . . . . . . . . . . . . . . . . . . . . . 13

Component Layout

. . . . . . . . . . . . . . . . . . . . . 11

Connector Pinouts and Pin Descriptions

. .10-11

Controls and Indicators

  . . . . . . . . . . . . . . . . . . 2

Decimal Point and Brightness Selection  . . . . . 5

Range Selection Mode. . . . . . . . . . . . . . . . . . .

7

Programming Conventions

. . . . . . . . . . . . . . . . 2

Setpoint Setting & Relay Configuration Mode

. . . .8-9

Software Features

  . . . . . . . . . . . . . . . . . . . . . . 1

Software Logic Tree . . . . . . . . . . . . . . . . . . . . . 3

Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . 1

Two Point Analog Range Setting & Calibration

. . . .

7

Digital Rescaling Procedures . . . . . . . . . . . . . . 4

Digital Span Selection for Display  . . . . . . . . . . 5

Digital Span Selection for Analog Range Output. . . 6

Functional Diagram

  . . . . . . . . . . . . . . . . . . . . 10

General Features

  . . . . . . . . . . . . . . . . . . . . . . . 1

I-Series Input Signal Conditioning Modules

  . . . . . 12

Installation guidelines

. . . . . . . . . . . . . . . . . . . 13

Ordering Information

  . . . . . . . . . . . . . . . . . . . 14

LEOPARD  

FAMILY

Input Specs: ������������������Depends on Input signal conditioner 

A/D Converter: ��������������14 bit single slope

Accuracy: ����������������������±(0�05% of r 2 counts)

Temp. Coeff�: �����������������100 ppm/°C (Typical)

Warm up time: ���������������2 minutes

Conversion Rate: ����������10 conversions per second (Typical)

Digital Display: ��������������4 digit 0.56" LED red (std), green (optn) 

Range –1999 to 9999 counts� 

Bargraph Display: ���������101 segment 235º circular red (standard)

Green (optional) or tricolor (optional) LED�

Polarity: �������������������������Assumed positive� Displays – negative

Decimal Selection: ��������Front panel button selectable, X•X•X•X• 

Positive Overrange: ������Bargraph and top segments of digital display 

flash�

Negative Overrange: ����First segment of bargraph and bottom seg-

ments of digital display flash�

Relay Output: ����������������Two 9 Amp Form C relays, two 4 Amp Form 

A relays or 

4 x 4 Amp Form A relays

Analog Output: �������������Isolated 16 bit user scalable mA or V

  OIC (mA out) ��������������4-20 mA @ 0 to 500Ω max loop resistance

  OIV (volts out) �������������� 0-10 V DC @ 500 Ω or higher resistance

Power Supply: ���������������AC/DC Auto sensing wide range supply

  PS1 (std) ��������������������85-265 VAC / 95-300 VDC, 50-400Hz 4.2W

 PS2 �����������������������������18-48 VAC / 10-72 VDC, 50-400Hz 4�2W

Operating Temp�: ����������0 to 50°C

Storage Temp: ���������������–20°C to 70°C

Relative Humidity: ��������95% (non condensing)

Case Dimensions: ��������Bezel (4.48"x4.48") 113.8x113.8mm 

Depth behind bezel (4.23") 107.46 mm 

Plus (0�48”) 12�24 mm for connectors

Weight: ���������������������������16 oz�, 1lb 4 oz when packed

Table of Contents

Summary of Contents for CL-B101D40HZ

Page 1: ...Mode Selection 6 Bargraph Color Programming Mode 9 Case Dimensions 13 Component Layout 11 Connector Pinouts and Pin Descriptions 10 11 Controls and Indicators 2 Decimal Point and Brightness Selection...

Page 2: ...irection indicated by the arrow When an alternative dotted line is shown this indicates that an alternative logic branch will be followed when a particular option is present When two buttons are shown...

Page 3: ...See Page 5 Goes directly to Zero setting if Analog Output is not installed 4 00 20 00 Range 99 99 9999 999 9 Select one of three Ranges 99 99Hz 999 9Hz or 9999Hz PROGRAMMABLE OFFSET AND SCALE FACTOR...

Page 4: ...6 meter may be rescaled without applying an external signal by changing the Offset and Scale factor Offset is the reading that the meter will display for a zero input The Offset may be set to any valu...

Page 5: ...this point the display skips directly to STEP G and toggles between Cto and oFF the software is detecting that the optional analog output hardware is NOT installed Digital Span Selection For Bargraph...

Page 6: ...h and AnLo analog low can be reversed to provide a 20 to 4mA output The digital span selected can be as small as two counts when using the analog output to function as a Control or Alarm Driver Small...

Page 7: ...volt output selected However the output of cLo must always be less than the value selected for chi If a reversed analog output is desired the values selected to establish the Digital Span can be reve...

Page 8: ...ress the P button Display toggles between PUM and on or oFF STEP F Select Pump PUM on or oFF 1 Using the and buttons select the Pump to be ON or OFF When PUM is selected ON and SP2 is set at a value h...

Page 9: ...argraph Color when the bar is ABOVE SP2 Setpoint 1 Using the and buttons select the desired bargraph color grn oran or red 2 Press the P button Display toggles between CSP3 and the previous color sett...

Page 10: ...mp Form A relays An analog output module is also shown as installed The CL B101D40HZ uses plug in type screw terminal connectors for all input and output connections The power supply connec tions pins...

Page 11: ...A SP4 SP3 SP2 SP1 SP1 SP2 SP3 SP4 Relay Modules with 4 Isolated 5A Form A Relays Output Carrier Board Output Carrier Board Relay Module Relay Module Input Signal Conditioner Analog Output Module Main...

Page 12: ...ditioning Modules COUPLING INPUT SIGNAL FILTER MAG NAMUR SOURCE SINK LOAD AC 20KHz 2KHz 200Hz OFF DC MAG AC LOGIC GND 24V INPUT High Accuracy Digital Measurement NPN Open Collector Proximity Switch No...

Page 13: ...t the meter from external noise Input output leads should be routed as far away as possible from contactors control relays transformers and other noisy components Shielding cables for input output lea...

Page 14: ...y 50 POWER SUPPLY PS1 85 265VAC 95 300VDC N C PS2 18 48VAC 10 72VDC 40 INPUT MODULES Partial List See www texmate com Unless otherwise specified Texmate will ship all modules precalibrated with factor...

Reviews: