Page 19
Apr-18-2016 DI-60A 320 DS (NZ302)_UL April 2016
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
X
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Step 1
Step 2
Step 3
Operational Display
Operational Display
Example
Press
2
Press
at same
time
Press
at same
time
Press
1
OR
Step 4
Press
at same
time
Press
at same
time
Step 6
0 Primary Display
1 Second Display (See Note)
2 Third Display (See Note)
3 Peak/Valley
4 Analog Output 1
5 Analog Output 2
6 Totalizer 1
7 Totalizer 2
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
OR
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
OR
Step 7
Step 8
Step 9
Press
1
Press
1
From Step 5
Step 5
Select [diSP] as the Data
Source from the options
listed in the Select Data Source
diagram above.
Set Code 1 to [X50]:
1st Digit = X Note relevant
2nd Digit = 5 Selects data source mode
3rd Digit = 0 Selects Primary Display
Select [000] to leave
Code 1
Save Data Source setting
Exit Code 2. Return to
Operational Display
Enter Brightness Mode
Pass Brightness and
Calibration Modes
and enter Code 1
X
CONFIGURE
DATA SOURCE
Go to Source
selection.
Go to the next
selection.
Example Procedure:
Configure the Primary Display with the display [diSP] as the
data source by setting Code 1 to [
X50
]. See diagram at the
bottom of the page for data source selection options.
Configure Data Source Procedure
The following example procedure describes how to select the
source of the data to be displayed for the third digit selection.
Programming Tip
To enter the Main Programming Mode press the
P
and
buttons at the same time. To exit and return to the
operational display, press the
P
and buttons again
at the same time.
At the end of any procedure (Step 8 in this procedure)
the
P
must be pressed before the
P
and buttons
are pressed,otherwise the meter returns to the opera-
tional display without saving the new settings.
Programming Tip
Pressing the
and
buttons at t h e
same time increases the
displayed parameter in
increments of 100 counts.
Programming Tip
Pressing the
button reaches
[000] faster.
Note:
Options 1 and 2 listed fir the 3rd digit in Step 3 above are only for use
with meters that have more than one display. With bargraph meters the
PRIMARY display is the digital display, and the SECONDARY display
is the bargraph display.
START HERE
Initial Setup Procedures
[CodE_1] - Display Configuration continued
Select Data Source
[TOT_1]
[TOT_2]
[TARE]
[VALLEY]
Use the buttons to cycle through the
Registers Menu and Registers (1 to 244)
to select data source for displays (also
see page 36).
[RESULT]
[CH1]
[CH2]
[CH3]
[CH4]
[PEAK]
[DISP]
[ 1]
[ 10]
[100]
[200]
[244]
P