Page 27
Apr-18-2016 DI-60A 320 DS (NZ302)_UL April 2016
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Press
1
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
CONFIGURE
CH4 FUNCTIONS
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Prog.
SP1
SP2
SP4
SP3
SP5
SP6
Step 1
Step 2
Step 3
Operational Display
Operational Display
Press
7
Press
at same
time
Press
at same
time
OR
Step 4
Press
at same
time
Press
at same
time
Step 5
CONFIGURING CH4 FUNCTIONS PROCEDURE
Pass Brightness Mode,
Calibration Mode, and
Codes 1 to 5 and enter
Code 6
From Step 4
Set Code 6 to [01X]:
1st Digit = 0 Selects direct display input
2nd Digit = 1 Selects voltage, current
3rd Digit = X Not relevant
Save CH4 setting
Exit Code 7.
Return to
Operational Display
Enter Brightness Mode
CODE 6 – CHANNEL 4 FUNCTIONS
FIRST DIGIT
SECOND DIGIT
THIRD DIGIT
FOR THERMOCOUPLE
0 Type J
1 Type K
2 Type R
3 Type S
4 Type T
5 Type B
6 Type N
7 Select user defined lineariza-
tion table (Table 1) set up in CAL
[24X]
FOR RTD TYPE (2-, 3-, 4- WIRE)
0 Resistance
1 RTD 385
2 RTD 392
3 RTD 120
4 Cn 10
MEASUREMENT TASK
0 No Function
1 Voltage / Current
2 TC (3rd digit selects type of
TC). See Note 7
3 RTD (3rd digit selects type of
RTD). See Note 7
4 Real Time Clock and Timer (3rd
digit selects type)
5 -
6 -
7 Smart Input Module (3rd digit
selects register)
FOR SMART INPUT MODULE
0 Output Register 1
1 Output Register 2
2 Output Register 3
3 Output Register 4
4 Output Register 5
5 Output Register 6
6 Output Register 7
7 Smart Input Module Register 3
Code Setup
Note 7:
For future development.
FOR REAL-TIME CLOCK & TIMER
0 HRS:MIN:SEC
1 HRS:MIN
2 -
3 -
4 1 2nd Count UP Timer
5 1 2nd Count DOWN Timer
6 -
7 -
Press
Use the
buttons to set the
required smart input module code
(0 to 377). See
I-Series Input
Modules Guide (Z87)
for code
details.
Code 6 is a single code that
combines all the configuration
and post processing functions
available for Channel 4.
When a
quad input
signal con-
ditioner is installed, the 4th input
signal is processed and dis-
played on CH4.
Post processing and measure-
ment task functions for CH4
are configured in the 1st, 2nd,
and 3rd digits of Code 6. The
diagram opposite lists the avail-
able configuration selections in
Code 6.
CH4 POST PROCESSING
0 Direct Display of Input (no pro-
cessing)
1 Square Root of Channel 4
2 Inverse of Channel 4
3 4 kB Meters
32-point Linearization of CH4 using
Table 1
32 kB Meters
32-point Linearization of CH4 using
Table 4
Note:
All linearization tables are set up
in the Calibration Mode [24X].
Example Procedure:
Configure CH4 as direct display of
voltage input by
setting Code 6 to [
01X
].
START HERE
Initial Setup Procedures
[CodE_6] - Channel 4 Functions
See
I-Series Input Modules Guide (Z87)
for pro-
cedures to set up a quad input module.
P