DL-40JANUS-SG manual (d0116)

Page 1

•  Two header selectable trans duc er output ranges of 2mV/V 

and 20mV/V. 

•  5V or 10V DC excitation provided by the meter
•  Optional isolated 14 bit analog output. User or factory 

scalable to 4 to 20 mA, 0 to 20 mA or 0 to 10 V across any 

desired digital span from ± one count to the full scale range 

of – 1999 to 9999 (12000 counts).

•  Optional Isolated Modbus RTU RS-485 serial communication 

with selectable baud rate (9600, 19200), address and parity.

•   Auto-sensing AC/DC power supply. For voltages between 
     

85-265 VAC / 95-300 VDC (PS1) 

or 15-48 VAC / 10-72 VDC (PS2).

•  Standard red or optional green or super bright red 4-digit LED 

with display range –1999 to 9999 (12000 counts).

•  Red or green 0.8” LED large display option
•  Four annunciator LEDs provide front panel alarm status  

indication for up to four setpoints.

•  Up to optional six relays in combination of six, four or two 4 

Amp Form A relays or two 9 Amp Form C with two or four 4 

Amp Form A relays are available.

•  Automatic intelligent averaging smooths noisy signals, while 

providing a fast display response to real input signal changes.

•  Three-button programming from the front panel  

(UP, DOWN and PROGRAM buttons).

Auto Calibration Mode . . . . . . . . . . . . 5

Auto Calibration Procedure . . . . . . . . 5

Case Dimensions . . . . . . . . . . . . . . . 12

Connector Pinouts . . . . . . . . . . . 10-11

Controls and Indicators . . . . . . . . . . . 2

Component Layout. . . . . . . . . . . . . . 12

Digital Span Selection for Analog

Range Output. . . . . . . . . . . . . . . . . . . 6

Decimal Point & Brightness Selection. . 6

General Features . . . . . . . . . . . . . . . . 1

Glossary of Programming Symbols . . 2

Installation Guideline . . . . . . . . . . . . 11

Lens Cover & Metal Surround Case 13

Manual Rescaling. . . . . . . . . . . . . . . . 4

Manual Rescaling Procedure. . . . . . . 4

Meter Assembly . . . . . . . . . . . . . . . . 10

Modbus RTU & RS-485 Settings . . . . 7

Modbus RTU Implementation  . . . . . . 7

Modbus Address for DL-40 Registers . . . 8

Ordering Information  . . . . . . . . . . . . 14

Setpoint & Relay Configuration Mode . . . .9

Software Features  . . . . . . . . . . . . . . . 1

Software Logic Tree . . . . . . . . . . . . . . 3

Specifications. . . . . . . . . . . . . . . . . . . 1

Two Point Analog Output Range 

Setting and Calibration. . . . . . . . . . . . 6

General Features

Specifications

Software Features

Index

LEOPARD FAMILY

DL-40JANUS-SG

Two scaling methods - MANUAL (no external sig-

nal source required) and AUTO (requied an exter-

nal signal source). Optional Modbus RS-485 serial, 

analog and up to six relays output. 

A powerful smart meter to measure  

4 wire/6wire pressure transducers, strain gauges.

•  Front panel selectable four-level brightness control for digital 

display and setpoint LEDs.

•  Four programmable setpoints.
•  Relay activation can be selected to occur above (HI) or below 

(LO) each setpoint.

•  Hysteresis setting for all four setpoints.  Delay on make and 

delay on break for SP1 and SP2.

•  Peak and Valley.  View and Reset.
•  Program Lock switch

4 Digit 0.56” or 0.8” LEDs

in a 1/8 DIN CASE

Input Configuration: .Differential

A/D Converter: ..........14 bit single slope

Accuracy: ..................±(0.05% of r 2 counts)

Temp. Coeff.: .............100 ppm/°C (Typical)

Warm up time: ...........2 minutes

Conversion Rate: ......5 conversions per second (Typical)

Display: ......................4 digit 0.56" Red LED display (std)

0.56” Green, 0.8" Red/Green, or  

0.56" Super Bright Red are optional. 

Range 0 to 9999 counts. 

Polarity: .....................Assumed positive. Displays – negative

Decimal Selection: ....Front panel button selectable, X•X•X•X•

Positive Overrange: ..Top segments of digital display flash

Negative Overrange: .Bottom segments of digital display flash

Relay Output: ............Up to Six Relays in combination of six, 

four or two 4 Amp Form A relays or two 

9 Amp Form C with two or four 4 Amp 

Form A relays. 

Analog Output: .........Isolated 16 bit user scalable mA or V

  AIC (mA out) ...........4-20 mA @ 0 to 500Ω max loop resistance

  AIV (volts out) .......... 0-10 V DC @ 500 Ω or higher resistance

Power Supply: ...........AC/DC Auto sensing wide range supply

  PS1 (std) ................85-265 VAC / 95-300 VDC, 50-400Hz @ 3W

 PS2 .........................15-48 VAC / 10-72 VDC, 50-400Hz @ 2.5W 

Operating Temp.: ......0 to 50 °C

Storage Temp: ...........–20 °C to 70 °C.  

Relative Humidity: ....95% (non condensing)

Case Dimensions: ....1/8 DIN, Bezel: 96x48 mm (3.78”x1.89”) 

Depth behind bezel: 117 mm  (4.61”) 

Plus 11.8 mm (0.47”)  for Right-angled 

connectors, or plus 20 mm (0.79”) for 

Straight-thru connector.

Weight: .......................6.5 oz., 8.5 oz when packed

Certification ...............UL Listed.

Summary of Contents for DL-40JANUS-SG

Page 1: ...utput Range Setting and Calibration 6 General Features Specifications Software Features Index LEOPARD FAMILY DL 40JANUS SG Two scaling methods MANUAL no external sig nal source required and AUTO requi...

Page 2: ...by pressing and releasing the or buttons When there are more than two display selec tions they are shown in brackets below the first display and are also selectable by press ing and releasing the or b...

Page 3: ...L POINT AND BRIGHTNESS SELECTION See Page 6 Setpoint 3 SP3 Setpoint 4 SP4 Valley Offset Scale Factor Calibrate Analog Output Lo Calibrate Analog Output Hi X XXX XX XX XXX X XXXX XXXX 2 3 4 Decimal Poi...

Page 4: ...t STEP B Select Between Calibration of Input or Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to se...

Page 5: ...Point Analog Output Note If the analog output option is not present Step B is skipped and the program goes directly from Step A to Step C 1 Press the or button to select the display toggling from CAL...

Page 6: ...s the P and buttons at the same time Display toggles between CAL and oFF 2 Press the P button Display shows previous dP selection STEP E Set the Decimal Point 1 Using the and adjust the display to the...

Page 7: ...unts and does not include the deci mal point If you need the decimal value with decimal point you will need to read the register convert it to decimal read 40024 see below to determine decimal locatio...

Page 8: ...ST2 Setpoint 2 Hysteresis setting 40019 0x0012 SINT16 R W 1999 9999 PRES3 Setpoint 3 setting 40020 0x0013 UINT16 R W 0 9999 HYST3 Setpoint 3 Hysteresis setting 40021 0x0014 SINT16 R W 1999 9999 PRES4...

Page 9: ...P2 Delay on Make doM Delay Time Setting STEP H Set the SP2 Delay on Break dob Delay Time Setting STEP I Set the Hysteresis Setting for Setpoint 2 1 Using the and buttons adjust the display to the desi...

Page 10: ...with external signal OFF 17 16 19 19 18 MANUAL rescaling ON AUTO scaling OFF ON SP1 NO SP1 NO SP2 NO SP2 NO Pins 14 and 15 AC DC Power Input Auto sensing AC DC power supply For voltages between 85 265...

Page 11: ...air circulation 3 Separate input output leads from power lines to protect the meter from external noise Input output leads should be routed as far away as possible from contactors control relays tran...

Page 12: ...71 1 8 DIN Cutout spacers 87 4mm 3 45 Various bezel colors are available Black is standard Prog SP3 SP4 SP2 SP1 For additional strength extra Mounting Slide Clips can be ordered and doubled up one beh...

Page 13: ...se is made from fire retardant polycar bonate A metal surround case can be ordered to enhance the meter s fire retardant capabilities and also provide shielding against electromagnetic interference EM...

Page 14: ...OA____ DL 40JANUS SG Add to the basic model number the order code suffix for each standard option required The last suffix is to indicate how many different special options and or accessories that you...

Reviews: