background image

FL-BDPSF-PROCESS (d0076) manual

Page 1

Smart 4-20mA/0-10V process Tri or Mono-

color digital bargraph with four fully program-

mable set points and

Isolated 4-20 mA analog output capability

•  Standard Input Rnage

 

– 4-20mA

 

IP01 : 

4-20mA Process Loop

 

IP02 : 

4-20mA Process Loop with Excitation  24VDC@100mA

 

– 0-10V 

 

ID01 : 

DC-Volts 2/20/200V with 24V DC Exc

 

ID05 : 

DC-Volts 2/20/200V with offset and 24V DC Exc

  Optional isolated 16 bit analog output. User or factory scalable to 4 

to 20 mA, 0 to 20 mA or 0 to 10 V across any desired digital span 

from ± one count to the full scale range of -1999 to 9999.

  A Programmable Tricolor (Red-Green-Orange) or mono color (red or 

green), 101 segment high brightness bargraph. Vertical or optional 

horizontal format.

  Red 4-digit LED display with a range of -1999 to 9999. Optional 

green digital display.

  Front panel LED annunciators provide indication of setpoint status.

  Two 9 Amp Form C, and two 4 Amp Form A relays available

  Provision to connect an external programming lockout switch. 

  Provision for external DIM switch to reduce the brightest 

display setting by 50%.

  Optional NEMA-4 front cover.

  Automatic intelligent averaging, smooths noisy signals while  

providing a fast display response to real level changes.

•  UL Listed

General Features

Specifications

Index

FL-BDPSF-PROCESS

•  The bargraph can display, full 

scale, any desired portion of 

the digital reading.

• 

Bargraph center zero function.

• 

Four programmable setpoints 

with adjustable Hysteresis.

•  Setpoint 1 has delay-on-make 

and delay-on-break plus 

a special “pump on pump 

off” mode that creates a 

Software Features

Hysteresis Band between SP1 

and SP2.

•  Relay activation can be select

-

ed to occur above (hi) or below 

(Lo) each setpoint.

•  Digital display blanking.

•  Decimal point setting.

•  Four-level brightness control 

accessed by the   button and 

adjusted by the   button.

Bargraph Center Point Display Mode Selection

  . . . 6

Bargraph Color Programming Mode  . . . . . . . . 9

Case Dimensions . . . . . . . . . . . . . . . . . . . . . . . 7

Component Layout. . . . . . . . . . . . . . . . . . . . . 11

Connector Pinouts . . . . . . . . . . . . . . . . . . . . . 10

Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Controls and Indicators  . . . . . . . . . . . . . . . . . . 2

Custom Faceplates and Scales

. . . . . . . . . . . 19

Decimal Point and Brightness Selection

  . . . . . 5

Programming Conventions. . . . . . . . . . . . . . . . 2

Setpoint Setting & Relay Configuration Mode

. . . .8-9

Software Features

  . . . . . . . . . . . . . . . . . . . . . . 1

Software Logic Tree

. . . . . . . . . . . . . . . . . . . . . 3

Specifications

. . . . . . . . . . . . . . . . . . . . . . . . . . 1

Standard Faceplates and Scales

. . . . . . . . . . 18

Two Point Analog Range Setting & Calibration

. . . . 7

Two Point Digital Calibration Mode  . . . . . . . . . 4

Digital Span Selection for Display

  . . . . . . . . . . 5

Digital Span Selection for Analog Range Output

. . . 6

Functional Diagram  . . . . . . . . . . . . . . . . . . . . 10

General Features  . . . . . . . . . . . . . . . . . . . . . . . 1

I-Series Input Signal Conditioning Modules

  . . .12-15

Input Module Calibration Procedures  . . . . . . 17

Input Module Component Glossary. . . . . . . . 16

Ordering Information  . . . . . . . . . . . . . . . . . . . 20

Pin Descriptions . . . . . . . . . . . . . . . . . . . . . . . 10

Input Specs: ��������������Series connection to 4-20mA process 

loop or Single ended 0-10V DC

A/D Converter: ����������14 bit single slope

Accuracy: ������������������±(0�05% of r 2 counts)

Temp. Coeff�: �������������100 ppm/°C (Typical)

Warm up time: �����������2 minutes

Conversion Rate: ������10 conversions per second (Typical)

Digital Display: ����������4 digit 0.31" LED red (std), green (optn) 

Range -1999 to 9999 counts� 

Bargraph Display: �����101 segment 4” red vertical (std),  

green or tricolor (optn), horizontal (optn)

Polarity: ���������������������Assumed positive� Displays – negative

Decimal Selection: ����Front panel button selectable, X•X•X•X• 

Positive Overrange: ��Bargraph and top segments of digital 

display flash�

Negative Overrange: First segment of bargraph and bottom 

segments of digital display flash�

Relay Output: ������������Two 4 Amp Form A relays and Two   

9 Amp Form C relays� 

Analog Output: ���������Isolated 16 bit user scalable mA or V

  OIC (mA out) �����������4-20 mA @ 0 to 500Ω max loop resistance

  OIV (volts out) ���������� 0-10 V DC @ 500 Ω or higher resistance

Power Supply: �����������AC/DC Auto sensing wide range supply

  PS1 (std) ����������������85-265 VAC / 95-300 VDC, 50-400Hz 4.2W

  PS2 �������������������������18-48 VAC / 10-72 VDC, 50-400Hz 4�2W

Operating Temp�: ������0 to 50°C

Storage Temp: �����������–20°C to 70°C

Relative Humidity: ����95% (non condensing)

Case Dimensions: ����9/64 DIN (Bezel 36Wx144Hmm) 

Depth behind bezel (5�83") 148mm 

Plus (0�7”) 18mm for connectors

Weight: �����������������������9�5 oz�, 12 oz when packed

101 Segment, 4 Digit 0.32” LEDs

in a 9/64 DIN CASE

Built-in Programmable Scale Factor

No Input required to calibrate

Summary of Contents for FL-BDPSF-PROCESS

Page 1: ...Mode 9 Case Dimensions 7 Component Layout 11 Connector Pinouts 10 Connectors 11 Controls and Indicators 2 Custom Faceplates and Scales 19 Decimal Point and Brightness Selection 5 Programming Conventio...

Page 2: ...ROGRAM button This is the UP button This is the DOWN button When a button is shown press and release it to go onto the next step in the direction indicated by the arrow When an alternative dotted line...

Page 3: ...lay Digital Display ON OFF Selection diSP Sub menu MODE Calibration Input Calibration Output Calibrate Analog Output Lo Calibrate Analog Output Hi Select the Digital Reading at which the Analog Output...

Page 4: ...SS meter may be rescaled without applying an external signal by changing the Offset and Scale factor Offset is the reading that the meter will display for a zero input The Offset may be set to any val...

Page 5: ...d oFF the software is detecting that the optional analog output hardware is NOT installed Digital Span Selection For Bargraph Display Decimal Point and Brightness Selection Bargraph does not light up...

Page 6: ...For Digital readings outside the Digital Span selected the analog output will not go lower than the calibrated value set for cLo 2 Press the P button The display toggles between cto and oFF Note Any...

Page 7: ...position changed see Component Layout below Note Always disconnect power from the meter before removing the analog output module to adjust the mA or Volts output selection header and reinstalling it...

Page 8: ...Press the P button Display toggles between PUM and on or oFF STEP F Select Pump PUM on or oFF 1 Using the and buttons select the Pump to be ON or OFF When PUM is selected ON and SP2 is set at a value...

Page 9: ...nd buttons select the desired bargraph color grn oran or red 2 Press the P button Display toggles between CSP3 and the previous color setting STEP T Select Bargraph Color when the bar is ABOVE SP3 Set...

Page 10: ...input signal conditioner Pins 8 to 15 Relay Output Pins Pin 8 SP3 NO Normally Open 4 Amp Form A Pin 9 SP1 3 COM Common for SP1 and SP3 Pin 10 SP1 NC Normally Closed 9 Amp Form C Pin 11 SP1 NO Normall...

Page 11: ...N 1 PIN 3 _ Exc On Off Header SPAN Pot HI LOW SPAN RANGE Header ZERO Pot ZERO ADJUST Header SPAN ADJUST Header ZERO OFFSET RANGE Header Decrease Increase Decrease Increase Lo Hi OFF ON 0 Input Range H...

Page 12: ...100 Counts 100 Counts 0 ZERO Potentiometer Pot If provided the ZERO pot is always to the left of the SPAN pot as viewed from the rear of the meter Typically it enables the input signal to be offset 5...

Page 13: ...pter enables modern DIN meters to fit in existing cutouts individually or stacked when replacing old 6 edgewise mechanical pointer meters Fits existing cut outs for 6 150 mm edgewise switchboard point...

Page 14: ...rinted on a special plastic film which is then laminated to custom faceplate blanks as required Large Run 300 pieces min custom face plates are produc tion silk screened issued a part number and held...

Page 15: ...s for input output leads is recommended with shield connection to earth ground near the meter preferred 4 A circuit breaker or disconnect switch is required to disconnect power to the meter The breake...

Page 16: ...Extra Screw Terminal Conn 3 Pin Plug 5 93 PLUG4P DR Extra Screw Terminal Conn 4 Pin Plug 6 93 PLUG5P DR Extra Screw Terminal Conn 5 Pin Plug 7 OP MTL144x36 Metal Surround Case includes screw mounting...

Reviews: