Mar-07-2016 DI-50AN6 320 DS (NZ303)_UL_March 2016
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
Page 19
Enter
Brightness
Mode
Step 1
Step 2
Step 3
Operational Display
Press
2
Press
at same
time
Press
at same
time
Step 4
Step 6
0 Primary Display
1 Second Display (See Note)
2 Third Display (See Note)
3 Peak/Valley
4 Analog Output 1
5 Analog Output 2
6 Totalizer 1
7 Totalizer 2
Step 7
Step 8
Step 9
From Step 5
Step 5
Select [diSP] as the Data Source
from the options listed in the Select
Data Source diagram below.
CONFIGURING THE DATA SOURCE PROCEDURE
Set Code 1 to [X50]:
1st Digit = X Note relevant
2nd Digit = 5 Selects data source mode
3rd Digit = 0 Selects primary display
Select [000] to leave
Code 1
Save Data Source setting
Pass Brightness and
Calibration Modes
and enter Code 1
OR
Example
Press
1
Press
at same
time
Press
at same
time
OR
OR
Exit
Code 2.
Return to
Operational
Display
Operational Display
X
X
Press
1
Press
1
CONFIGURE
DATA SOURCE
Programming Tip
Pressing the
and
buttons at t h e
same time increases the
displayed parameter in
increments of 100 counts.
Programming Tip
Pressing the
button reaches
[000] faster.
Example Procedure:
Configure the Primary Display with the display [diSP] as the
data source by setting Code 1 to [
X50
]. See diagram at the
bottom of the page for data source selection options.
Configure Data Source Procedure
The following example procedure describes how to select the
source of the data to be displayed for the third digit selection.
Programming Tip
To enter the Main Programming Mode press the
P
and
buttons at the same time. To exit and return to the
operational display, press the
P
and
buttons
again at the same time.
At the end of any procedure (Step 8 in this procedure)
the
P
must be pressed before the
P
and
buttons
are pressed,otherwise the meter
returns
to the operational display without saving the new set-
tings.
Note:
Options 1 and 2 listed fir the 3rd digit in Step 3 above
are only for use with meters that have more than one
display. With bargraph meters the PRIMARY display is
the digital display, and the SECONDARY display is the
bargraph display.
START HERE
Initial Setup Procedures
[CodE_1] - Display Configuration continued
Use the
buttons to
cycle through the Registers
Menu and Registers (1 to
244) to select data source for
displays (also see page 36).
Select Data Source
P
[rESLt]
[Ch1]
[Ch2]
[Ch3]
[Ch4]
[tot_1]
[tot_2]
[PEAK]
[tArE]
[VALEY]
[diSP]
[ 1]
[ 10]
[100]
[200]
[244]